Installation SPIDER II 16TX
Release 02 12/2014
To mount the device onto a horizontally mounted 35 mm DIN rail according
to DIN EN 60715, proceed as follows:
Slide the upper snap-in guide of the device into the DIN rail.
Press the media module downwards onto the clip-in bar.
Snap in the device.
2.2.2
Grounding the device
The device is grounded via a 5-pin terminal block.
Note:
Ground the device before connecting any other cables.
Note:
The shielding ground of the connectable twisted pair cables is
connected to the ground connection as a conductor.
Beware of possible short circuits when connecting a cable section with
conductive shielding braiding.
WARNING
ELECTRIC SHOCK
Ground the device before connecting any other cables.
Failure to follow these instructions can result in death, serious injury,
or equipment damage.