GUIDE TO INSTALLATION AND OPERATION
MDX-3901 |
29
5.7 Monitoring panel
5.7.1 RALM tab
The Remote Audio Level Meter (RALM) panel displays audio
output level meters for up to 8 channels. Channels are
displayed in pairs, so up to four stereo meters will be present
in the meter display window. The source for each meter is
selected using the pulldowns in the RALM Remote Control
area at the bottom of the control panel.
OFF
CH 1&2 up to 7&8, or CH 9&10 up to 15&16 (depends
on the Group selection value)
The meter is divided into three zones, and the dividing points
and color of each zone are individually configurable under the
Meter Ballistics Config
tab.
Speed
–
select the meter response from the pull-down list,
options are [ fast, medium, slow ]
5.7.1.1 RALM Connections tab
Use the radio buttons to turn the meter display ON (RALM) or
OFF for the indicated channels. The meter appears directly
above the controls.
Reset Counter:
click this button to reset the overload counter
on the ALM display to zero. See the next section for
instructions on setting up the overload counter.
5.7.1.2 Meter Ballistics Config tab
Type
– select a type of meter from the pull-down list
Upper Zone Limits
– select the crossover level between
the upper and middle zones of the meter (the range of
values shown in the pull-down list depends on the type of
meter selected)
Lower Zone Limits
– select the crossover level between
the middle and lower zones of the meter (the range of
values shown in the pull-down list depends on the type of
meter selected)
Color samples
– the three samples show the current selected color for the upper, middle and lower zones of the meter.
Click on the color sample of a zone to open a color selection panel to choose a different color for that zone
Figure 5.16 RALM - meter ballistics configuration
Figure 5.15 Monitoring - RALM tab