GUIDE TO INSTALLATION AND OPERATION
HDA-1911/1931 |
7
2 Installation
2.1 Installation of Rear Connector Panels
Miranda Densité-series cards are each associated with a rear connector panel, which must be installed in the Densité
frame before the card can be inserted.
The HDA-19x1 card is sized to fit into Miranda
’s Densité-2 frame. Eight different rear connector panels are available
to fit the Densité 2 frame:
HDA-19NN-SRP
Single rear for 1x4 operating mode.
HDA-19NN-SRP-R
Single rear for 1x4 operating mode with bypass protection relay.
HDA-19NN-SRP-F
Single rear for 1x2 operating mode with fiber option support.
HDA-19NN-DRP
Double rear for 1x9 operating mode.
HDA-19NN-DRP-R
Double rear for 1x9 operating mode with bypass protection relay.
HDA-19NN-DRP-F
Double rear for 1x8 operating mode with fiber option support.
HDA-193N-DRP
Double rear for dual 1x4 operating mode (HDA-1931 only).
HDA-193N-DRP-F
Double rear for dual 1x3 operating mode with fiber option support (HDA-1931 only).
With the use of an available adapter (Densité 3
– EXT B), the HDA-19x1 can also be installed in a Densité-3 frame
(see section 2.3 below). Two rear connector panels for this frame are available for the HDA-19x1:
HDA-191N-3SRP
Single rear for 1x7 operating mode.
HDA-193N-3SRP
Single rear for dual 1x3 operating mode (HDA-1931 only).
The eight Densité-2 rear panels can also be used in a Densité-3 frame, with the addition of available adapters:
HDA-19NN-SRP + DENSITE-SRP-3RU
Single rear for 1x4 operating mode.
HDA-19NN-SRP-R + DENSITE-SRP-3RU Single rear for 1x4 operating mode with bypass protection relay.
HDA-19NN-SRP-F + DENSITE-SRP-3RU
Single rear for 1x2 operating mode with fiber option support.
HDA-19NN-DRP + DENSITE-DRP-3RU
Double rear for 1x9 operating mode.
HDA-19NN-DRP-R + DENSITE-DRP-3RU Double rear for 1x9 operating mode with bypass protection relay.
HDA-19NN-DRP-F + DENSITE-DRP-3RU Double rear for 1x8 operating mode with fiber option support.
HDA-193N-DRP + DENSITE-DRP-3RU
Double rear for dual 1x4 operating mode (HDA-1931 only).
HDA-193N-DRP-F + DENSITE-DRP-3RU
Double rear for dual 1x3 operating mode with fiber option
support (HDA-1931 only).
All cards and rear panels can be installed with the frame power on. The card has connectors which plug into a mid-
frame mother board for distribution of power and for connection to the controller card, and a second connector which
plugs directly into the rear connector panel for input and output.