3.4.6 The
Alarms
panel
This panel allows the alarm reporting of the HDA-19x1 to be configured.
Click on the Alarm Config button to open the Alarm Configuration window.
The Alarm Configuration window is organized in columns
Status/Name
This contains an expandable tree listing all the alarms reported by this HDA-19x1 card.
Each alarm name includes an icon that shows its current status
The
Card LED
,
Overall alarm
and
GSM contribution
columns contain pulldown lists that allow the level of
contribution of each individual alarm to the alarm named in the column heading to be set.
If there is no arrowhead in the box, there is no pulldown and the alarm is not user-configurable
Card LED
This column allows configuration of the contribution of each individual alarm to the status reported by the Status
LED on the front edge of the HDA-19x1 card, visible through the front door of the Densité frame.
Overall Alarm
This column allows configuration of the contribution of each individual alarm to the Overall Alarm associated with
this card. The Overall Alarm is shown in the upper left corner of the iControl panel, and also appears at the bottom
of the Status/Name column.
GSM Contribution
This column allows configuration of the contribution of each individual alarm to the GSM Alarm Status associated
with this card. GSM is a dynamic register of all iControl system alarms, and is also an alarm provider for external
applications. The possible values for this contribution are related to the Overall alarm contribution:
If the Overall alarm contribution is selected as Disabled, the GSM alarm contribution can be set to any available
value
If the Overall alarm contribution is selected as any level other than disabled, the GSM contribution is forced to
follow the Overall Alarm.
Figure 3.9