Installation
8
DRYPOINT RA 200 – 2500 NA
2.2.
Storage
S
C
C
0
0
0
1
Even when packaged, keep the machine protected
from severity of the weather.
Keep the dryer in vertical position, also when stored.
Turning it upside down some parts could be
irreparably damaged.
If not in use, the dryer can be stored in its packaging
in a dust free and protected site at a maximum
temperature of 120°F (50°C), and a specific humidit y
not exceeding 90%. Should the stocking time exceed
12 months, please contact the manufacturer.
The packaging materials are recyclable. Dispose of material in compliance with the rules and
regulations in force in the destination country.
2.3.
Installation site
CAUTION!
Ambient conditions!
Failure to install dryer in the proper ambient conditions will affect the dryer’s ability to condense refrigerant
gas. This can cause higher loads on the compressor, loss of dryer efficiency and performance, overheated
condenser fan motors, electrical component failure and dryer failure due to the following: compressor loss,
fan motor failure and electrical component failure. Failures of this type will affect warranty considerations.
Do not install dryer in an environment of corrosive chemicals, explosive gasses, poisonous gasses; steam
heat, areas of high ambient conditions or extreme dust and dirt.
In case of fire, use an approved fire extinguisher,
water is not an acceptable means in cases of
fire.
Minimum installation requirements:
Select a clean dry area, free from dust, and protected from
atmospheric disturbances.
•
The supporting area must be smooth, horizontal and able to
hold the weight of the dryer.
•
Minimum ambient tempe34 °F (+1 °C).
•
Maximum ambient tempe120 °F (+50 °C).
•
Allow at least a clearance of 40 in (1m) on each side of the
dryer (80 in - 2m DRYPOINT RA 1500-2500 NA dryers) for
proper ventilation and to facilitate eventual maintenance
operations.
The dryer does not require attachment to the floor surface;
however installations where the unit is suspended require
an attachment to the hanging apparatus.
Содержание DRYPOINT RA 1000/AC NA
Страница 37: ...List of attachments DRYPOINT RA 200 2500 NA 37 7 2 2 Exploded view DRYPOINT RA 200 350 NA ...
Страница 38: ...List of attachments 38 DRYPOINT RA 200 2500 NA 7 2 3 Exploded view DRYPOINT RA 400 500 NA ...
Страница 39: ...List of attachments DRYPOINT RA 200 2500 NA 39 7 2 4 Exploded view DRYPOINT RA 600 1250 NA ...
Страница 40: ...List of attachments 40 DRYPOINT RA 200 2500 NA 7 2 5 Exploded view DRYPOINT RA1500 2500 NA ...
Страница 51: ...List of attachments DRYPOINT RA 200 2500 NA 51 ...