DRYPOINT
®
M eco control
9.2. FAQ
Error or fault pattern
Possible causes
Remedy
Poor degree of drying
Temporary overload
Improve the operating conditions e.g.
increased working pressure, prevent sudden
load changes
Incorrect dimensioning
Implement larger dryer
Aerosol ingress
Inspect filter element function and, where
applicable, exchange it or introduce an
additional preliminary filter; inspect
condensate drain-off function and replace it
if necessary
Purge air flow blocked internally
Contact manufacturer: If necessary, return
device for repair
Sensor is too old
Contact manufacturer: If necessary, return
device for repair and/or replace control unit
Incorrect operating mode selected
Amend the operating mode
Coating formation on the sensor caused by
low quality of the flowing in air
• Improve compressed air quality on
membrane dryer inlet
•
Adhere to the filter element
maintenance interval and replace the
element regularly
• Exchange control unit
• Return the device to the manufacturer
for repair
Purge air outlet is always
open (“fail-safe”)
Continuous overload
Improve operating conditions e.g. increase
working pressure, avoid sudden load
changes; check dryer dimensions; use larger
unit
Fail-safe mode active
Inspect error and fault messages: The
flashing rate of the red LED indicates the
type of the fault; if necessary, contact
manufacturer
Incorrect installation direction
Inspect installation direction of device
Software error
Contact manufacturer: If necessary, return
device for repair and/or replace control unit
Sensor defective
Contact manufacturer: If necessary, return
device for repair and/or replace control unit
Power failure (power LED off)
Reconnect to the voltage supply
Power control board defective
Contact manufacturer: If necessary, return
device for repair and/or replace control unit
Device overheating
The device automatically resumes
its operating state when the internal
temperature has dropped < 60°C
Piston seal defect
Replace set of wear parts, see chapter
“7.1.4. Wear part exchange” on Page 39
Measuring gas jet is blocked
Contact manufacturer: If necessary, return
device for repair and/or replace control unit
Solenoid coil burnt through
Change solenoid coil, see chapter “7.1.4.
Wear part exchange” on Page 39
Purge air outlet constantly
closed (measuring gas flow
only)
Incorrectly dimensioned unit
Use smaller dryer
Sensor defective
Contact manufacturer: Return device for
repair and/or replace control unit