7.1.4. Wear part exchange
The device includes a solenoid valve and a piston valve whose seals are dynamically stressed; they are subject to wear and
must therefore be exchanged cyclical.
The service life of these parts is many million switchings, however, it depends strongly on the actual runtime of the plant
and possibly also on the air contaminants.
The following values are listed as guide values for the preventive maintenance:
•
Single shift operation (260 work days/year)
average service life 2 years
•
Continuous operation 24/7
average service life 1 year
The normal wear at these parts - surface abrasion or deformations at the seat areas - has no impact on the function.
The full purge air volume flows continuously and the control function has no impact if the wear of the seals is too large or if
the seals are destroyed, e.g. due to the impact of aggressive compressed air ingredients or significant ageing.
This system condition is not detected by the device as a failure (red LED not lit) because the requirements for the set degree
of drying are fulfilled.
A required exchange of the wear parts during the warranty period does therefore not establish a warranty claim, but it
represents normal maintenance effort.
Please contact the service of
BEKO TECHNOLOGIES GmbH
if maintenance cycles are required significantly more often for
specific applications/installations.
Prerequisites
Tools
Material
Protective equipment
•
Allen key Ø 2 mm
•
Allen key Ø 2.5 mm
with ≥ 100 mm shaft length
•
Allen keyØ 4 mm
with ≥ 100 mm shaft length
•
Set of wear parts
4040729
•
4041283
•
None
Preparatory tasks
1.
1.
Depressurise the device and secure against pressure being applied again:
Depressurise the device and secure against pressure being applied again:
2.
2.
De-energise the device and secure it against being switched back on again.
De-energise the device and secure it against being switched back on again.
Remove the mains plug.
Remove the mains plug.
A “click” noise indicates the opening of the solenoid valve.
A “click” noise indicates the opening of the solenoid valve.
Pressure drop is taking place in the device.
Pressure drop is taking place in the device.
3.
3.
Prepare workplace for the exchange of the wear parts.
Prepare workplace for the exchange of the wear parts.
NOTE
Damages possible
Damages of the device or the electronic printed circuit board as well as crushing or breakage of
cables can occur during the wear part exchange.
• While working, prevent the development of mechanical tensions, which can damage the
electronic printed circuit board or the cables.