4. Technical data
4.1 Operating parameters
BEKOMAT
®
14i
14i CO
14i CO PN25
Ambient relative humidity
10 … 80 %, without condensation
Maximum operating height
2000 m
2187.23 yd
Minimum / maximum operating pressure
0.8 … 16 bar(g)
12 … 230 psi(g)
1.2 … 25 bar(g)
18 … 362 psi(g)
Minimum / maximum operating temperature
+1 … +60 °C
+34 … +140 °F
Average discharge rate
33.33 l/h
8.80 gal/h
Maximum discharge rate (short-term)
350 l/h
92.46 gal/h
Connection*, Condensate inlet
3 x G3/4, internal
maximum screw-in depth: 13.5 mm (1/2 in)
Connection, condensate discharge
1 x G1/2 external,
hose connection for hose diameter
10 … 13 mm (0.39 … 0.51 in), internal
1 x G3/8 internal
Media
Condensate, oil-
contaminated
Condensate, oil-contaminated or oil-free
Empty weight
2.9 kg
6.4 lbs
3.1 kg
6.8 lbs
Operating voltage
24 VDC ±10 %
(see type plate)
Power consumption
P <8.0 VA (W)
Degree of protection
IP65
Housing class (UL50E)
TYPE 13
Overvoltage category (IEC 61010-1)
III
Degree of pollution (IEC 61010-1)
3
Recommended cable diameter
5 … 10 mm
0.23 … 0.33 in
Recommended wire cross-section
0.25 … 1 mm²
AWG 18 … 24
Recommended shortening of the cable jacket
~ 50 mm
~ 1.97 in
Recommended stripping length of the cable wires
~ 6 mm
~ 0.24 in
* The NPT thread version is optional.
Original installation and operation manual
BEKOMAT
®
14i / 14i CO / 14i CO PN25
27 | 76
Содержание BEKOMAT 14i
Страница 73: ...Original installation and operation manual BEKOMAT 14i 14i CO 14i CO PN25 73 76 ...
Страница 74: ...16 2 Declaration of Conformity BEKOMAT 14i 14i CO 14i CO PN25 Original installation and operation manual 74 76 ...
Страница 75: ...Original installation and operation manual BEKOMAT 14i 14i CO 14i CO PN25 75 76 ...