CATASTROPHIC ERRORS
A catastrophic failure is generated each time the AC Power Supply experiences a hardware failure.
Errors are cleared whenever the AC Power Supply transmits a response, except in the case of a
short circuit fault which may only be cleared by cycling power to the AC Supply.
Catastrophic Error Messages
All begin with:
F00ACS0(DEV):
This message is followed by one explanatory message from the
following text:
OVERTEMP FAULT <cr><lf><eos>
The heatsink temperature has exceeded its upper limit. The
OVERTEMP LED on the front panel will light.
CURRENT LIMIT FAULT <cr><lf><eos>
SHORT CIRCUIT FAULT: AC SUPPLY<cr><lf><eos>
An output loading fault has occured causing the supply to exceed 500%
rated current output. The supply automatically shuts down and opens its
output relay. The OVERLOAD LATCH LED on the front panel will light.