2.3
3 PHASE INPUT POWER REQUIREMENTS
The BL10000 series power supplies within the model number range C2 to C6 are designed to be used with a
four wire “ Wye” input configuration. Units that are to be supplied with “Delta” inputs above 277 volts require the
use of “back-up” fuses to provide supplemental protection. This is due to the interrupt rating of the circuit
breaker used. The chart below indicates the proper fuse based on the model number of the power supply. This
chart can also serve as a guide for sizing the input service to the unit.
The following lists should be used to select the proper line fuse size for the model numbers shown. The
selections are based on nominal line voltages and maximum output power. All fuses carry a 600 VAC minimum
voltage rating.
BACK-UP FUSES TO BE USED ON DELTA CONNECTIONS ABOVE 277 VAC
MODEL #
L-L VOLTAGE
FUSE SIZE
PART NUMBER
BL 10000 - C1
208V
37 A max
not required
BL 10000 - C2
380V
30AMP / 600V
108-201-025
BL 10000- C3
480V
25 AMP/ 600V
108-201-024
BL 10000- C5
600 V *
20 AMP/ 600V
108-201-023
BL 10000- C6
400V
30 AMP/ 600V
108-201-025
* Wye or Delta requires supplemental protection
Figure 2-1 . Inter-connect diagram for standard 3 phase input.
Содержание BL10000 Series
Страница 9: ...3 THIS PAGE BLANK FOR ADDENDUMS ALL MANUAL ADDENDUMS WILL FOLLOW THIS PAGE ...
Страница 17: ...11 Figure 3 1 BL10000 AC Source Control Chassis Front and Rear Panel Views ...
Страница 49: ...6 1 SECTION 6 DRAWINGS ...
Страница 50: ......
Страница 51: ......
Страница 52: ......
Страница 53: ......
Страница 54: ......
Страница 55: ......
Страница 56: ......
Страница 57: ......
Страница 58: ......
Страница 59: ......