7B
REV. C
B-4
Table 1-1
CILL SOFTWARE COMMANDS (cont)
CILL COMMANDS
EXPLANATION
FTH VOLT
<cr><lf>
The AC supply responds to this command by transmitting the RMS
voltage (in volts resolute to 0.1V) measured at its output, in decimal
format as follows:
<sp><digit><digit><digit><dp><digit><cr><lf>
FTH CURR
<cr><lf>
The AC Supply responds by transmitting the current (in amps
resolute to 0.1A) measured at its output, in decimal format, as
follows:
<sp><digit><digit><dp><digit><cr><lf>
FTH FREQ
<cr><lf>
The AC Supply response by transmitting the frequency (in hertz)
measured at its output, in decimal format, as follows:
<sp><digit><digit><digit><cr><lf>
CLS :CH /0
<cr><lf>
Closes output relay contacts. Connects AC Power Supply outputs
to output terminal block. The setup command specifies the voltage
and frequency. The setup command must be entered before the
CLS :CH /0
command.
OPN :CH /0
<cr><lf>
Opens output relay contacts. Disconnects output of AC Power
Supply from output connector. AC Power Supply retains voltage
and frequency assigned by setup command.
RST ACS
:CH/0
Resets AC Power Supply to quiescent. The output relay opens and
error messages are erased.
Catastrophic error messages are cleared by reading the Power
Supply's response, by use of the Status command.
CNF
<cr><lf>
Instructs AC Power Supply to perform internal confidence test. STA
command transmits the message. The AC Power Supply responds
with one of the following:
Pass
<sp><cr><lf>
Fail
F/07ACS/0(DEV): CONFIDENCE TEST FAILURE
<cr><lf>
Содержание BL10000 Series
Страница 9: ...3 THIS PAGE BLANK FOR ADDENDUMS ALL MANUAL ADDENDUMS WILL FOLLOW THIS PAGE ...
Страница 17: ...11 Figure 3 1 BL10000 AC Source Control Chassis Front and Rear Panel Views ...
Страница 49: ...6 1 SECTION 6 DRAWINGS ...
Страница 50: ......
Страница 51: ......
Страница 52: ......
Страница 53: ......
Страница 54: ......
Страница 55: ......
Страница 56: ......
Страница 57: ......
Страница 58: ......