GT-600/GT-800 Instruction Manual
24
Substitute Leakage Current Test (I
SUB
)
The substitute leakage current test measures the leakage current between L/N
terminals of test socket and PE terminal of test socket in parallel with PROBE 2
(at class I, class II). L/N terminals are shorted by the tester for this test.
It is essential to refer to the local appliance test standards and/or guidance
material for the safe applicability of this test.
Remarks:
Connect the appliance and the test lead according to the figure 13 or 14.
For class I appliances no probe is required except if there are some metal
parts on the appliance not connected to PE terminal.
For class II appliances apply the test probe to any exposed metalwork on the
appliance. Do the test for all exposed metal parts on the appliance.
Figure 13: Substitute leakage current test connections at appliance class I
Figure 14: Substitute leakage current test connections at appliance class II