Commissioning
EL5032, EL5032-0090
93
Version: 2.4
6.4.3
Predefined PDO Assignment
The "Predefined PDO Assignment" enables a simplified selection of the process data. The desired function is
selected on the lower part of the "Process Data" tab. As a result, all necessary PDOs are automatically
activated and the unnecessary PDOs are deactivated.
4 PDO assignments are available:
Name
SM3, PDO assignment
1 Ch. Standard
(FB Inputs Channel 1)
1 Ch. Compact
(FB Inputs Channel 1 compact)
2 Ch. Standard
(FB Inputs Channel 2)
2 Ch. Compact
(FB Inputs Channel 2 compact)
Fig. 103: Process data tab - Predefined PDO Assignment, EL5032
6.4.4
Overview of commands and samples
can be used to initiate various actions, such as reading
from, or writing to a particular memory range of the EnDat encoder (see table)
Command Description
CoE Entry / sample
0x1000
Clearing the diag history (see
note below)
0x1001
Diag History Test
All implemented Diag messages
are sent channel-dependent with
this message.
Command entry via the System Manager
If the command input is written via the System Manager, the value must be entered in the "Binary"
field (LOBYTE first, see Fig.
Entry of the command in the Set Value dialogue of the System Man-
ager
). If the command is triggered via the PLC, it is executed automatically.