Commissioning
EL5032, EL5032-0090
105
Version: 2.4
Index A0p8 FB EnDat Diag data (for Ch.1, p = 0; Ch.2, p = 1)
Index (hex) Name
Meaning
Data type
Flags
Default
A0p8:0
FB EnDat Diag data
Max. subindex
UINT8
RO
> 67 <
A0p8:01
Warning
Warning bit of the EnDat protocol
FALSE: no warning
TRUE: indicates that a warning has occurred (collective
message)
BOOLEAN
RO
FALSE
A0p8:02
Error 1
Error 2 bit of the EnDat protocol
FALSE: no error message 1
TRUE: indicates that an error message 1 has occurred
(collective message)
BOOLEAN
RO
FALSE
A0p8:03
Error 2 (active low)
Error 2 bit of the EnDat protocol
FALSE: no error message 2
TRUE: indicates that an error message 2 has occurred
(collective message)
BOOLEAN
RO
FALSE
A0p8:04
Reference Mark
FALSE: reference travel not completed
TRUE: reference travel completed. Already set when
switching on in case of absolute measuring devices
BOOLEAN
RO
FALSE
A0p8:11
CRC Error Position
counter
Incremented with each “CRC error position”
Reset during re-initialization
UINT16
RW
0x0000 (0
dec
)
A0p8:12
CRC Error Z1 counter Incremented with each “CRC error additional information
1”
Reset during re-initialization
UINT16
RW
0x0000 (0
dec
)
A0p8:13
CRC Error Z2 counter Incremented with each “CRC error additional information
2”
Reset during re-initialization
UINT16
RW
0x0000 (0
dec
)
A0p8:21
Light source error
lighting
FALSE: OK
TRUE: failure
BOOLEAN
RO
FALSE
A0p8:22
Signal amplitude error Signal amplitude
FALSE: OK
TRUE: erroneous
BOOLEAN
RO
FALSE
A0p8:23
Position error
Position
FALSE: OK
TRUE: erroneous
BOOLEAN
RO
FALSE
A0p8:24
Overvoltage error
Overvoltage
FALSE: none
TRUE: yes
BOOLEAN
RO
FALSE
A0p8:25
Undervoltage error
Undervoltage
FALSE: none
TRUE: supply undervoltage
BOOLEAN
RO
FALSE
A0p8:26
Overcurrent error
Overcurrent
FALSE: no
TRUE: yes
BOOLEAN
RO
FALSE
A0p8:27
Battery error
Battery
FALSE: OK
TRUE: change required
BOOLEAN
RO
FALSE
Содержание EL5032
Страница 1: ...Documentation EL5032 EL5032 0090 2 channel EnDat2 2 Interface 2 4 2019 10 30 Version Date...
Страница 2: ......
Страница 44: ...Mounting and wiring EL5032 EL5032 0090 44 Version 2 4 Fig 31 Other installation positions...
Страница 54: ...Commissioning EL5032 EL5032 0090 54 Version 2 4 Fig 42 Incorrect driver settings for the Ethernet port...