Appendix
EL5032, EL5032-0090
131
Version: 2.4
Example with ser. no.: 12 10 03 02:
12 - week of production 12
10 - year of production 2010
03 - firmware version 03
02 - hardware version 02
Determining the version via the System Manager
The TwinCAT System Manager shows the version of the controller firmware if the master can access the
slave online. Click on the E-Bus Terminal whose controller firmware you want to check (in the example
terminal 2 (EL3204)) and select the tab
CoE Online
(CAN over EtherCAT).
CoE Online and Offline CoE
Two CoE directories are available:
•
online
: This is offered in the EtherCAT slave by the controller, if the EtherCAT slave supports this.
This CoE directory can only be displayed if a slave is connected and operational.
•
offline
: The EtherCAT Slave Information ESI/XML may contain the default content of the CoE.
This CoE directory can only be displayed if it is included in the ESI (e.g. "Beckhoff EL5xxx.xml").
The Advanced button must be used for switching between the two views.
In Fig.
Display of EL3204 firmware version
the firmware version of the selected EL3204 is shown as 03 in
CoE entry 0x100A.
Fig. 122: Display of EL3204 firmware version
In (A) TwinCAT 2.11 shows that the Online CoE directory is currently displayed. If this is not the case, the
Online directory can be loaded via the
Online
option in Advanced Settings (B) and double-clicking on
AllObjects
.
8.2.3
Updating controller firmware *.efw
CoE directory
The Online CoE directory is managed by the controller and stored in a dedicated EEPROM, which
is generally not changed during a firmware update.
Switch to the
Online
tab to update the controller firmware of a slave, see Fig.
Firmware Update.
Содержание EL5032
Страница 1: ...Documentation EL5032 EL5032 0090 2 channel EnDat2 2 Interface 2 4 2019 10 30 Version Date...
Страница 2: ......
Страница 44: ...Mounting and wiring EL5032 EL5032 0090 44 Version 2 4 Fig 31 Other installation positions...
Страница 54: ...Commissioning EL5032 EL5032 0090 54 Version 2 4 Fig 42 Incorrect driver settings for the Ethernet port...