Basics of EnDat 2.2 technology
EL5032, EL5032-0090
33
Version: 2.4
4.5
Data transfer
A clock is provided by the subsequent electronics for the synchronization of the data transmission. In the idle
state the clock line is at the HIGH level.
Clock frequency – cable length
With the runtime compensation employed in the EL5032, a cable length of maximally 100 m is possible with
a clock frequency of 8 MHz. Correspondingly suitable cables and plug connectors must be used in order to
guarantee the function.
Further information on EnDat technology
Further notes and information on the HEIDENHAIN company’s EnDat technology can be found at
http://www.heidenhain.de
**) Source: