Menu
item
Menu
value
Function / value
Basic
values
Setting
A5
SAFETY INPUT SE2: FUNCTION
Travel in CLOSE direc-
tion:
Travel in OPEN direc-
tion:
00
No effect
No effect
01
Stop
No effect
02
Reverse travel
No effect
03
Reopening
No effect
03
04
No effect
Stop
05
Stop
Stop
06
Reverse travel
Stop
07
Reopening
Stop
08
No effect
Reverse travel
09
Stop
Reverse travel
10
Reverse travel
Reverse travel
11
Reopening
Reverse travel
12
No effect
Reclosing
13
Stop
Reclosing
14
Reverse travel
Reclosing
15
Reopening
Reclosing
A6
AUTOMATIC RECLOSING
00
Off
00
01..10 Stay-open time 5...50 s, in 5 s increments, excl.
advance warning time
11..40 Stay-open time 11=1 min, 12=2 min, … 40=30 min
excl. advance warning time
A7
STAY-OPEN TIME AFTER EXITING THE LIGHT
BARRIER (SE2)
00
Function switched off
00
01..20 Stay-open time 1...20 s, in 1 s increments
18