If no changes in the menu values are possible, the entire
control panel is protected against readjustment. Enable
via item "Disable/enable parametrisation".
The drive cannot operate during the adjustment.
Menu table
Basic values = factory setting
Menu
item
Menu
value
Function / value
Basic
values
Setting
A0
RUNNING TIME LIMITATION
00..90 Maximum drive running time 1...90 s, in 1 s incre-
ments
60
91..99 Maximum drive running time 1...9 min, in 1 min in-
crements
A1
LIMIT POSITION DETECTION
00
Running time
without
drive current monitoring
(observe "Type of limit position detection via run-
ning time or limit switch" without fail!)
01
Running time and drive current monitoring
01
A2
SAFETY INPUT SE1: Type
00
No SE safety edge connected
01
LS (without external testing)
02
LS (with external testing)
03
1K2
04
8K2
04
05
OSE
06
OSE (special: 400 Hz / 12 V)
16