![BayTech Telplex TX102 Скачать руководство пользователя страница 65](http://html.mh-extra.com/html/baytech/telplex-tx102/telplex-tx102_owners-manual_2713144065.webp)
59
59
Enter the desired string (up to 42 characters). If String 1 must include
control characters, use the prefix
^
(5E hex or ASCII 94) to represent the
Control
key. For example, if you want the string to include
Control-T
, you
would enter
^T
in response to the prompt along with the rest of the
desired string. The entry must be followed by the <ENTER> key.
NOTE:
All AT commands require a
Carriage Return
at the end of the
command(s) before the modem will execute the command(s).
Therefore,
^M
(
Control-M
or
Carriage Return
) should be the last
character entered in either programmable string.
For example, if you want the local unit to send String 1 to instruct the
external modem to tone dial the remote unit's external modem at number
1-555-123-4567 upon power-up or loss of DCD, you would first enter the
following string:
Enter Up to 42 Characters to be Sent for String:
ATDT15551234567^M
The Telplex will respond with:
+--------+------------------------------------------+----------+
| String | Programmable String | Send On: |
+--------+------------------------------------------+----------+
| 1 | ATDT15551234567^M | Manual |
+--------+------------------------------------------+----------+
| 2 | | Manual |
+--------+------------------------------------------+----------+
String 1.......................1 String 1 Send On........3
String 2.......................2 String 2 Sent On........4
Enter request or X to Exit:
If you wish to change the condition on which String 1 will be sent out the
composite port, type "3" (String 1 Send On) in response to the prompt at
the end of the Programmable String submenu. The Telplex will respond
with:
1 For Power Up
2 For DCD Off
3 For Power/DCD
4 For Manual
Enter Request:
Содержание Telplex TX102
Страница 24: ...18 20 DTR Input Data Terminal Ready Enable disable the receiving of characters ...
Страница 41: ...35 Self test passed ...
Страница 55: ...49 Press any Key to continue ...
Страница 58: ...52 Set Stop Bits 4 Set RTS DSR Pass Through 8 Enter Request ...
Страница 72: ...66 Figure 9 ...
Страница 83: ...77 wish to use 3 wires and XON XOFF handshaking only You may use the pinouts above for any HP plotter ...
Страница 99: ...NOTES NOTES ...