24
24
4.1.2.5
4.1.2.5
SERIAL PORT DESTINATION
SERIAL PORT DESTINATION
NOTE:
This section does not apply to standard Telplex units.
Serial Port Destination is the remote Telplex terminal port a local
terminal port will connect to once a communication link is established.
The Serial Port Destination consists of the remote Telplex's Unit
Number, Module Number and Port Number. The Unit Number may
range from 1 to 32, the Module Number may range from 1 to 16 and the
Port Number may range from 1 to 8.
Factory default is Unit 1, Module 1, Port X, where X is the local unit
port number (1 to 8).
4.1.2.6
4.1.2.6
UNIT NUMBER
UNIT NUMBER
NOTE:
This section applies to multi-drop units only.
Unit Number is used to identify multiple Telplex units and to direct
terminal port data. Unit Number informs a local Telplex that data coming
in from a remote unit is to be routed to a local port. If a remote terminal
port is to communicate with a local terminal port, the remote terminal port
would have the local Unit Number as part of its Serial Port Destination.
The Telplex Unit Number may range from 1 to 32.
Factory default is
Unit 1.
Содержание Telplex TX102
Страница 24: ...18 20 DTR Input Data Terminal Ready Enable disable the receiving of characters ...
Страница 41: ...35 Self test passed ...
Страница 55: ...49 Press any Key to continue ...
Страница 58: ...52 Set Stop Bits 4 Set RTS DSR Pass Through 8 Enter Request ...
Страница 72: ...66 Figure 9 ...
Страница 83: ...77 wish to use 3 wires and XON XOFF handshaking only You may use the pinouts above for any HP plotter ...
Страница 99: ...NOTES NOTES ...