34
34
4.3.4.2
4.3.4.2
DIAGNOSTICS MODE FOR
DIAGNOSTICS MODE FOR
STANDARD UNITS
STANDARD UNITS
Diagnostics mode for a standard unit is accessed from the Remote
Configuration Mode menu. This menu is accessed from the Local Mode
menu (see
Section 4.3.1
) by tying
Control-R
from the active terminal.
The Telplex will respond with the Remote Configuration Mode menu as
follows
Communicating to Remote Unit, Enter ^X to Cancel
Bay Technical Associates
Model TX108 Statistical Multiplexer
Copyright 1990-1992
Revision 1.04
Remote Configuration mode
Status......................................1
Serial Port Configuration...................2
Block Size, Local Access & Status Messages..3
Run Diagnostic..............................4
Programmable Strings........................5
Exit........................................X
Enter Request:
Type "4" in response to this menu (Run Diagnostic) and the Telplex will
respond with the "Run Diagnostic" menu as follows:
Self-Test........................................1
Full duplex communication to a select port.......2
Loop Back communication on a select port.........3
Exit.............................................X
Enter Request:
Select the desired diagnostic. For example, if you type "1" (Self-Test),
the Telplex will perform diagnostics on various components of the
remote unit. While the self-test is in progress, the local unit will send the
following message:
Please wait while self-testing...
If the remote unit passes its self-test, the Telplex will send back the
following message:
Содержание Telplex TX102
Страница 24: ...18 20 DTR Input Data Terminal Ready Enable disable the receiving of characters ...
Страница 41: ...35 Self test passed ...
Страница 55: ...49 Press any Key to continue ...
Страница 58: ...52 Set Stop Bits 4 Set RTS DSR Pass Through 8 Enter Request ...
Страница 72: ...66 Figure 9 ...
Страница 83: ...77 wish to use 3 wires and XON XOFF handshaking only You may use the pinouts above for any HP plotter ...
Страница 99: ...NOTES NOTES ...