background image

 

Page

  

 

DS62

 

Ethernet

 

Host

 

Module

 

 
 

 

 
 
 
 

DS62

MD4

 

Ethernet

 

&

 

56K

 

Modem

 

Host

 

Module

 

 
 

 

 
 
 
 
 
 
 
 
 

 

 

Содержание BayTech DS62

Страница 1: ...2019 COPYRIGHT 2019 Bay Technical Associates Inc 2 1 2019 DATA SWITCH DS62 DS62 MD4 ...

Страница 2: ...Page 2 DS62 Ethernet Host Module DS62 MD4 Ethernet 56K Modem Host Module ...

Страница 3: ...15 LOGGED USERS 15 MEMORY USAGE 15 CURRENT ROUTING CACHE 15 ROUTE SETUP 16 PROCESSES 16 UNITINFO DATABASE 16 NETWORK CONFIGURATION MENU 16 STATUS 17 SERIAL PORT CONFIGURATION 19 Handshaking 19 Baud Rate 20 Word Size 20 Stop Bits 20 Parity 21 RTS DTR Line Driver Inactivity State 21 Modem DCD Connection Mode DS62 MD4 ONLY 21 SERIAL PORT DEVICE NAME 22 ATTENTION CHARACTER 22 DISCONNECT TIMEGUARD 22 C...

Страница 4: ...LOAD 40 Enable Firmware Upgrade 40 Enable SSL Cert Upload 40 Enable Configuration File Upload 41 Restore Configuration Defaults 41 Get Current Configuration File 42 Display Configuration Error Log 42 Enable Rel Ctl Firmware Upgrade 42 DS62 MD4 Modem Configuration Menu 43 Rings to Auto Answer 44 Modem Connectivity Timeout 44 Modem Inactivity Timeout 45 Modem Configuration Menu Option 5 Modem Device...

Страница 5: ... in the loss of communications or to highlight the proper functioning of equipment NOTE This term is used to denote items of interest to the user cr Carriage Return or ENTER The information in this document is subject to change without notice The statements configurations technical data and recommendations in this document are believed to be accurate and reliable but are presented without express ...

Страница 6: ...pon request Bay Tech Part No 25FRJ45PC 4 The 8 pin crossed modular cable is configured to operate with these adapters Using a straight 10 100 Base T cable connect the RJ 45 port labeled ETHERNET on the HOST module to an RJ 45 port on the network hub The LINK link integrity LED located on the front panel of the HOST illuminates when a good connection is established between the HOST and the hub A Fl...

Страница 7: ...nts PRÉPARATION DE L EMPLACEMENT D INSTALLATION Le secteur d installation devrait être propre et exempt des températures et de l humidité extrêmes Permettez le suffisamment d espace derrière l unité de DS pour des raccordements de câblage et de réceptacle L accès à l emplacement d installation devrait être limité au personnel autorisé L installation de ces unités devrait être limitée à ITE et à en...

Страница 8: ...e CAUTION For PERMANENTLY CONNECTED EQUIPMENT a readily accessible disconnect device Circuit Breaker rated not to exceed the amperage rating of the unit shall be incorporated in the fixed wiring between the power source and the Baytech unit For PLUGGABLE EQUIPMENT the socket outlet shall be installed near the equipment and easily accessible The outlets providing power to the unit shall be protecte...

Страница 9: ...le Signal RS 232 Port DS RS 232 Port RPC COM Port DE 9 Pin COM Port DB 25 Pin Signal DTR 1 1 4 20 DSR GND 2 2 1 GND RTS 3 3 7 5 CTS TXD 4 4 3 2 RXD RXD 5 5 2 3 TXD DSR 6 N C 6 6 DTR GND 7 7 5 7 GND CTS 8 8 4 RTS DTR 4 DCD DCD 8 1 8 DTR RI 9 22 RJ08X007 Standard Rollover Cable RJ45 to RJ45 Serial 2 RJ08X007 Pin out Serial 3 RJ45 Receptacle Plug ...

Страница 10: ...port to the adapter via the RJ08X007 rolled flat ribbon cable Use terminal emulation software to access the unit 9600 bps 8 data bits 1stop bit and no parity B C switch set to B NOTE At any time during the session you need to go to another menu use the Attention Character semi colon Press the attention character key 5 times to get back to the main status menu NOTE Password feature is case sensitiv...

Страница 11: ...ep If you wish to assign a static IP address to this unit disable the DHCP and go to step 17 14 Press Enter until you are asked to Accept Changes Type Y to accept changes or N to decline changes 15 After Accepting or Declining Changes you should get the Network Access Menu Figure 1 16 Select Unit reset to update the external connections Once the reset is completed 1 minute connect the Baytech devi...

Страница 12: ...ot attention character thereby preventing unwanted port disconnection Connect Port ID Echo 6 Echo port name or module port Login Setup 7 Login Menu Serial Telnet Radius TACACS access control manage users Network Port Configuration 8 Network Port IP Address Module Name 9 Change name of module RPC Management 10 Set up Voltage Current Sensor threshold Firmware Config Download 11 Update Firmware SSL C...

Страница 13: ... that are between 8 and 31 characters long Enter request CR to exit menus A Add user 1 root Network setup Ethernet Address 00 C0 48 00 01 FD IP Address 70 150 140 89 Subnet Mask 255 255 255 224 Default Gateway 70 150 140 65 Connection Inactivity Timeout mins Disabled Carriage Return Translation Enabled Break Length msecs 350 DHCP is Disabled Telnet is Enabled SSH is Enabled SSH host keys are set t...

Страница 14: ...del the menus may vary according to the number of DS74 modules installed in the unit If this is not an initial set up and Password has already been enabled you are prompted to login After logging in successfully invoke the main menu by sending the attention character five times NOTE Username Password feature is case sensitive Default is root baytech NOTE Only the Administrator user will see the co...

Страница 15: ...OM INTERNAL CONN STATUS PID 1 root localhost Normal 23 C 2 root 70 150 140 69 Normal 490 3 root 70 150 140 66 Normal 492 Strike T CR to terminate a connection process CR to continue Select 3 to show the name of the user account the type of interface serial or network and the status of the active sessions Enter number of connection to terminate CR Terminate a session by typing T at the prompt The u...

Страница 16: ...he unit will prompt for a PID number to terminate PID PORT STAT SIZE SHARED CPU COMMAND 1 S 133K 0K 0 2 init 2 S 0K 0K 0 0 keventd 6 S 0K 0K 0 0 kupdated 11 R 43K 0K 99 3 baytechd 12 S 13K 0K 0 1 mdmautologind 13 S0 S 13K 0K 0 1 bin autologind 14 S 14K 0K 0 0 bin inetd 17 S 133K 0K 0 1 rpccmdd 18 S 13K 0K 0 0 snmppolld 19 S 1833K 0K 0 0 snmpd 25 S0 R 71K 0K 1 0 ds62 Strike T CR to terminate a conn...

Страница 17: ...Set up Voltage Current Sensor threshold Firmware Config Download 11 Upload FTP firmware upload and download unit configuration Modem Configuration 12 DS64 MD4 Module ONLY Exit X CR Enter Request Installed Modules 01 Attention Character is Disconnect Time Guard is Disabled Port ID Echo is Disabled Module Name is Universal RPC Network Connectivity Login Configuration Ethernet Address 00 C0 48 35 DD ...

Страница 18: ...Server Address 0 0 0 0 TACACS Secret HardlyASecret TACACS encryption is Enabled DS62 Usernames as Backup is Disabled TACACS Server Port is 49 TACACS DS62 privilege level is Disabled TACACS DS62 privilege level 15 Modem Status Port Device Device Baud Word Stop Parity Handshake LineDrive Type Name Rate Size Bits DTR RTS 2 MODEM Host V90 Modem 115 2K 8 1 None None LO LO Rings to AutoAnswer 2 Modem Co...

Страница 19: ...Size 3 Stop Bits 4 Parity 5 RTS Line Driver Inactive State 6 DTR Line Driver Inactive State 7 Modem DCD Connection Mode 8 DS62 MD4 Module ONLY Enter Request 1 For a simple communication between modems three connected lines are needed TX Rx and Ground For the data to be transmitted both sides have to be clocking the data at the same baud rate While this method is sufficient for most applications it...

Страница 20: ... DTR line indicating that a connection has been made across the phone line This is read in through the DSR line and the modem can begin to send data The general rule of thumb is that the DTR DSR lines are used to indicate that the system is ready for communication where the RTS CTS lines are used for individual packets of data The word size is the measurement of the actual data bits in a transmiss...

Страница 21: ...ice to determine if noise is corrupting the data or if the transmitting and receiving devices clocks are out of sync With no parity selected it s assumed that there are other forms of checking that will detect any errors in transmission No parity also usually means that the parity bit can be used for data speeding up transmission In modem to modem communication the type of parity is coordinated by...

Страница 22: ...ccess the network main menu Select 4 from the Network Configuration Menu to change the attention character The unit displays the following The Default is a semi colon Attention Character is Enter Attention Character Select 5 from the Network Configuration Menu ensures reliable binary data transmission by providing a one second Timeguard after the unit receives the attention character If more data ...

Страница 23: ...keep same setting Select 3 for Modem login Type Y to enable Login Prompt Type N to disable prompt Press Enter to keep same setting Login prompt for telnet is Enabled Enable Y N CR for no change Login prompt for serial is Disabled Enable Y N CR for no change If the login has been enabled you will get a prompt similar to the following The default user and password is root and baytech all lower case ...

Страница 24: ...ser 1 user1 2 root Enter Request 2 Select a user number the Unit displays the following menu Change Password 1 Modify Port Access Rights 2 Exit X Enter Request 1 Select 1 to change a user s password The Unit displays the following menu User name root Enter old password CR if none If the user does not have a password the DS62 will respond for a new password and a confirmation to re enter the new pa...

Страница 25: ...1 Radius Server Address 2 Radius Backup Server Address 3 Radius Secret 4 Enable DS62 usernames as backup 5 Radius Login Timeout 6 Radius Server Port 7 Exit X CR Select 1 Radius Enable enables radius authentication If enabled the primary radius server address must be specified Select 2 Radius Server Address specifies the radius server IP addresses Select 3 Radius Backup Server Address specifies the...

Страница 26: ...written TACACS Encryption Enable 6 Enable Disable encryption TACACS login Timeout 7 Sets Time units waits for response TACACS Server Port 8 Assign secure TCP port DS62 Privilege Level Enable 9 Enable Disable TACACS privilege DS62 Privilege Level 10 Set Privilege Level 1 15 Exit X CR Select 4 from the Login Setup Menu displays the TACACS Configuration menu Setting up TACACS To enable TACACS for log...

Страница 27: ...cret assigns a secret word shared between the TACACS server and this unit A secret can be up to 16 characters and must be exactly the same as the secret stored on the server Select 5 EnableDS62 usernames as backup allows an unsecured access in case all specified radius servers are unavailable Select 7 TACACS Login Timeout sets the amount of time the unit will wait for a response from the TACACS se...

Страница 28: ... hang up and the unit dials the assigned number back when using a secure phone line Dial Back User Configuration Main Menu Enter User Number to modify User Name Phone Number Dly s En Dis 1 root 10 Dis Enter Request 1 Dial Back Configuration User Name Phone Number Dly s En Dis 1 root 10 Dis Dial Back Option 1 Phone Number 2 Dial Back Delay 3 Enter Request 1 Select a user number and the unit display...

Страница 29: ...these functions SSH host key Generator allows the user to generate a host key which is used in the SSH encryption process IP Filter allows or blocks specific IP Addresses SNMP provides a message format for communication between a computer and your devices and Web Server Configuration allows web access and sets up options for each Network setup Ethernet Address 00 C0 48 00 01 FD IP Address 70 150 1...

Страница 30: ...all SSH and Telnet sessions Select 3 to change the Gateway address Failure to enter the address in the decimal form causes the unit to display the following until it is entered correctly Default Gateway address is 0 0 0 0 Enter Gateway address in dotted decimal form Select 4 from Network Port Configuration Menu to set the amount of time the unit will wait before disconnecting if there is no activi...

Страница 31: ...n Menu the IP Filter Management Menu allows the admin user to pass or block certain IP Addresses If you have no rules defined the unit may display only options A E C Select 10 from Network Port Configuration Menu to allow the user to generate a unique SSH host key for the RPC unit This key is part of the SSH encryption process Each RPC leaving Baytech is shipped with same default SSH host key It i...

Страница 32: ...NMP program Information provided is for the SNMP Agent only Baytech Support will assist with the Agent part only For SNMP Manger assistance refer to the vender manual or contact the vender of the SNMP software you are using NOTE There are a number of shareware MIB Browsers that can be downloaded from the internet to make changes and receive traps for a quick verification test NOTE To use the SNMP ...

Страница 33: ...r new Trap Host IP Address Read Gives read access to authorized management stations to all objects in the MIB except the community strings but does not allow write access Write Gives read and write access to authorized management stations to all objects in the MIB but does not allow access to the community strings SNMP community strings authenticate access to MIB objects and function as embedded p...

Страница 34: ...ress on a web browser to get the unit web page i e http 70 150 140 95 NOTE The web page is a quick test to see if SNMP protocol is working in the unit if SNMP has been enabled IMPORTANCE Currently all users who access the unit through the web page have administrator privilege unless a TACACS server and privilege levels are used for authentication Select 13 from the Network Port Configuration Menu ...

Страница 35: ...lue in tenths of a volt i e 1300 130 0 volts Sel M P Identifier Hi V Lvl 1 2 1 MSP10 1300 Select 4 to change the alarm for low current Enter the Selection Sel Number and press Enter Type a value in tenths of a volt i e 100 10 0 amps Sel M P Identifier Low Curr 1 2 1 MSP10 0 Enter threshold value in tenths of unit measurement degrees etc Enter voltage threshold value in tenths of a volt Enter low c...

Страница 36: ...nd 4 enable the SNMP traps to be sent if the corresponding threshold had been exceeded Select 2 to set parameters for the different probe types This feature is useful for standardization and the probe type is known Environmental Sensor Configuration Menu Sel M P Identifier 1 2 1 MSP10 2 All Sensors Enter Request 2 Option 1 and 3 sets the temperature levels to the tenth of a degree Option 2 and 4 e...

Страница 37: ...a new outlet group Each outlet is represented by Mod Port Outlet i e Mod 2 dot port dot outlet number 1 2 1 1 The unit displays the following and asks for a name for the new Group Select 3 to delete a specific outlet group select the number of the group to be deleted The unit will display Group Deleted Select 4 to rename an outlet group s name select the number of the group to be renamed The unit ...

Страница 38: ...er Threshold settings Select 8 from the RPC Management Menu to display the unit s power efficiency on the web page and through SNMP The user sets a minimum power level that will send an SNMP trap to the SNMP Manager The smaller the power factor less than 1 more current is needed wasted to do the same amount work M P Module port Identifier Unit Id Circuits number of circuits on unit Outlets number ...

Страница 39: ...above minimum power threshold A value of 0 disables threshold Value will be applied to all circuits and outlets MMX units Enter threshold value Select 3 from the RPC Management Menu allows user to set all circuits and outlets to the same Power Threshold levels MMX refers to the metered outlet modular series Default Value 50w Minimum power required to generate an SNMP power factor trap if power fac...

Страница 40: ...replaced with one that better suits the user s environment The file format is checked after download to insure that the certificate is valid Enabling this will allow the SSL Certificate to be updated via ftp Enable SSL Certificate Upload Y N The unit will display the following IMPORTANT If you type Y the unit will display the following To stop this function power cycle the unit to close the SSL Ce...

Страница 41: ...he following below To stop this function power cycle the unit to close the Configuration File Upload Enabling this will allow the system configuration to be updated via ftp THE UNIT WILL RESET AFTER CONFIGURATION IS COMPLETE Enable Configuration File Upload Y N Waiting to receive configuration file At this point FTP the file into the unit A successful file upload and the unit will display configur...

Страница 42: ...isplay A YES response and the unit will display the following var confupload file created and ready for ftp retrieval Waiting to send configuration file At this point FTP the file to your computer A Successful file retrieval and the unit displays get of configuration file complete Unsuccessful file retrieval and the unit displays error in config upload file or transfer operation Select 7 to upgrad...

Страница 43: ...d the file as a modem file i e ZModem Verify the file transfer is ASCII Modem Port Configuration 1 Rings to Auto Answer 2 Modem Connectivity Timeout 3 Modem Inactivity Timeout 4 Modem Device Name 5 PPP Configuration 6 Country Code 7 Enter Request Select 1 the Modem Port Configuration and the Host Module displays the following menu The Default configuration is 9600 8 1 none Port Device Device Baud ...

Страница 44: ...stop bits 1 For 1 2 For 2 Enter Request Select parity 1 For None 2 For Even 3 For Odd Enter Request Select 2 from the Modem Configuration menu changes the Rings to Auto Answer and sets the number of rings before the unit answers The module displays the following The default setting is 2 Rings to Auto Answer 2 Enter number 1 4 Select 3 from the Modem Configuration Menu changes the Modem Connectivit...

Страница 45: ...e the CHAP feature Default is Disabled Select 5 to enable the CHAP Secret password feature minimum of 16 character Default is baytech Enter Dial In IP Address in dotted decimal form Select 6 from the Modem Configuration Menu the PPP is similar to the dial in modem used by telephone DSL or local cable access PPP establishes a negotiated connection between two devices Once connected an assigned IP a...

Страница 46: ... Argentina 07 Australia 09 Austria FD Belgium FD Brazil 16 Canada B5 Chile 99 China B5 Czech Re FD Denmark FD France FD Germany FD Greece FD Hong Kong 99 Hungary FD Iceland FD India 99 Indonesia 99 Israel B5 Italy FD Japan 00 Korea Re B5 Lithuania FD Malaysia 6C Mexico B5 Netherlands FD New Zealand 7E Norway FD Philippines B5 Poland FD Portugal FD Romania FD Russian Fe FD Singapore 9C Slovenia FD ...

Страница 47: ...roduct is in excellent condition A product may not be returned after 30 days from the original date of shipment unless approved by BayTech management For additional information or more specific warranty issues contact BayTech s Technical Support or Customer Service Departments at 800 523 2702 or 228 563 7334 This warranty does not cover misuse or minor imperfections that fall within design specifi...

Страница 48: ... Long Beach MS 39560 Telephone 800 523 2702 or 228 563 7334 FAX 228 563 7335 Email support baytech net Website www baytech net Return policy refers to BayTech products purchased and returned for credit or repair A Return Authorization RA number must be obtained in all cases before returning the BayTech product Have the serial number and reason for the return or description of the problem handy Cus...

Страница 49: ...original packaging or similar packaging The warranty does not cover damage sustained during shipment Enclose a letter with name address RA number daytime phone number and description of the problem c Mark the RA number clearly on the outside of the package d Ship the unit by insured prepaid carrier to the following address Bay Technical Associates 5239 A Avenue Long Beach Industrial Park Long Beac...

Страница 50: ...og in OK Log in is validated by the TACACS RADIUS server Case 3 TACACS RADIUS disabled or TACACS RADIUS contact loss Enable DS62 usernames as backup enabled user Log in OK DS62 validates the user Case 4 TACACS RADIUS disabled or TACACS RADIUS contact loss Enable DS62 usernames as backup disabled user Log in FAIL Neither TACACS RADIUS nor the DS62 can validate the user Parameters to determine if us...

Страница 51: ...and the faceplate towards you 3 Locate jumper JMP5 approximate center of circuit board 4 Move the jumper from pins 1 and 2 to pins 2 and 3 5 Put the module back in the chassis and wait 30 seconds 6 Take the module back out and replace the jumper to the original position pins 1 2 Note If the module appears not to have reset or opening menu has random characters in it perform the reset procedure aga...

Страница 52: ... a Verify you see or hear the modem negotiating b Verify the telecommunications line is a true analog line and not a digital converted to analog c If the modem negotiates then drops the call serial into the unit Verify the Country Code for the modem is set for the local country code 6 Verify DS chassis Host Module and DS74 is functioning A rollover cables pin out 1 8 2 7 3 6 4 5 5 4 6 3 7 2 8 1 an...

Страница 53: ...Radius Configuration C 7 4 Radius Enable C 7 4 1 Radius Server Address C 7 4 2 Radius Backup Server Address C 7 4 3 Radius Secret C 7 4 4 Enable DS62 usernames as backup C 7 4 5 Radius Login Timeout C 7 4 6 Radius Server Port C 7 4 7 o TACACS Configuration C 7 5 TACACS Enable C 7 5 1 TACACS Server Address C 7 5 2 TACACS Backup Server Address C 7 5 3 TACACS Secret C 7 5 4 Enable DS62 usernames as b...

Страница 54: ...ify Outlets in a Group C 10 6 5 Delete All Outlet Groups C 10 6 6 o Temperature units degrees C F C 10 7 o Power Factor Threshold C 10 8 Individual Unit Power Facter and Power thresholds C 10 8 1 All Inputs Circuits Outlets Power Factor Threshold C 10 8 2 All Inputs Circuits Outlets Power Threshold C 10 8 3 Firmware Config Download C 11 o Enable Firmware Upgrade C 11 1 o Enable SSL Cert Upload C 1...

Отзывы: