Detail Operations and Configurations
NETWORK
MENU
DS-Series - F 2.10.05 (C) 2005 Bay Technical Associates
Module Name: DS62-MD4
Module: 1
Attention Character: ;
Device A (2 ,1).........1
Device B (2 ,2).........2
Device C (2 ,3).........3
Device D (2 ,4).........4
DS-RPC (5 ,1).........5 Displayed for
DS-RPC units ONLY
Status...................S Current configuration
Configure................C Make Changes
Unit Reset...............RU Resets the DS-Unit, terminates internal &
external modem connections, allow 10
seconds for reset.
Logout...................T
Enter Request :c
IMPORTANT:
The Factory default serial communications parameters are
9600 bps, 8 data
bits, 1 stop bit, and no parity.
With a proper serial port connection, upon power-up or unit reset, the following Status menu will be
displayed. The number of devices displayed is dependent on the number of DS74 modules installed.
NOTE:
Depending on the DS-Series model, the menus may vary according to the number of
DS74 modules installed in the unit. If this is not an initial set-up and Password has already been
enabled, you are prompted to login. After logging in successfully, invoke the main menu by
sending the attention character five times (
;;;;;
).
NOTE:
Username/Password feature is case sensitive. Default is
‘root/baytech’
.
NOTE:
Only the Administrator user will see the configuration option.
NOTE:
If select the “Configure” option and get the following message
(
Configuration mode in use
), the other port has the configuration option selected.
IMPORTANT:
Any changes made in the Configuration menu will NOT take effect until
changes are accepted. Type “X” and press ‘Enter” until the unit displays a prompt: {Accept
Changes? (Y/N)}. Type “Y” to accept changes. The unit will display: (Changes Accepted)
Press ‘Enter” to get out of the configuration menu. If the DS62 does not automatically reset,
type “RU” (Unit Reset) at the prompt and press ‘Enter’ This action will update the configuration
in the RAM.