1-13
Remote Annex 2000 Hardware Installation Guide
Chapter 1 Introduction
❑
Environment:
❑
Operating temperature: 0
°
to 50
°
C.
❑
Non-operating temperature: -25
°
to 65
°
C.
❑
Operating humidity: 5% to 95% relative humidity,
non-condensing.
❑
Non-operating humidity: 5% to 95% relative humidity,
non-condensing.
❑
Operating shock: 10G peak 1/2 sine wave, 11 ms
duration.
❑
Operating vibration: random vibration 1.2 *10
-3
G
2
/Hz,
12 to 198 Hz.
❑
Audible noise: A-Weighted Sound Pressure level less
than 36 dB @ 1 meter from all 6 surfaces.
❑
Operating altitude: 0 to 4000 meters.
❑
Storage altitude: 0 to 15,000 meters.
❑
Transportation vibration and shock: NSTA project 1A
standard in shipping container.
❑
Approvals:
❑
Meets safety requirements of ETL (US and Canada),
UL1950, CSA C22.2 No. 950, and EN60950.
❑
Meets EMI requirements of FCC Class A and EN55022
Class A with shielded and unshielded cables. Meets EMI
requirements of EN55022 Class B with shielded cables.
❑
Meets EMC requirements of EN50082-1.