4-9
Remote Annex 2000 Hardware Installation Guide
Chapter 4 Troubleshooting Procedures
Test Mode Error Sequences
describes the state of the LEDs if errors occur at different
stages of the start-up process. For example, if the Remote Annex 2000
fails while testing the hardware (state T2), the error condition is
hardware failure TE2. A description of each error condition follows
.
Table 4-4. Test Mode Error LED States
Key:
●
On continuously.
✕
Off.
■
Flashing irregularly.
◆
Flashing regularly (about 1Hz).
Activity
Power
green
Unit
green
Net
green
Attn
amber
Load
green
Active
green
TE2:
Hardware failure
●
◆
✕
◆
✕
✕
TE3: Network test
failure
●
●
◆
✕
✕
■
TE4: Network test
aborted or net
command failed
●
●
✕
◆
✕
■
TE7: Booted
wrong image
●
●
●
◆
✕
✕