13
C607215 - GB
INSTRUCTIONS FOR USERS
BLOCK
In the presence of a block, the display
shows the symbols
the flashing letters
>>>OK
which flash alternately (about eve-
ry 2 seconds) with the <
ERROR
> message.
The block is identified by an error code fol-
lowed by the letter
E
.
Press
OK
to reset the electronic board and
restore operation.
The display shows the message <
RESET
>
and then the message
>>>OK
.
0608_2805
0812_1904
To keep the boiler efficient and safe, have it checked by the authorised Service Centre at the end of every operating period. Careful servicing ensures
economical operation of the system.
Do not clean the outer casing of the appliance with abrasive, aggressive and/or easily flammable cleaners (e.g.: petrol, alcohol, and so on). Always
switch off the appliance before cleaning it (see section 6 “Switching off the boiler”).
10. ROUTINE MAINTENANCE INSTRUCTIONS
Error code
01e
02e
03e
04e
05e
06e
11e
12e
13e
25e
31e
35e
80e-96e
98e
99e
Description of fault
Failed ignition shutdown
Safety thermostat tripped
Flue thermostat/ flue pressure switch tripped
Safety error for frequent losses of flame
Delivery probe failure
DHW sensor fault
Tripping of safety thermostat for system at low temperature
(if connected)
Lack of consent from hydraulic differential pressure switch
Hydraulic differential pressure switch contact faulty
Safety intervention for no water circulation
Communication error between electronic board and climate
controller
Parasite flame (flamer error)
Climate controller internal error
Board internal error
Board internal error
Corrective action
Press
OK
. If this fault occurs repeatedly, call the authorised service
centre.
Press
OK
. If this fault occurs repeatedly, call the authorised service
centre.
Call the Authorised Service Centre.
Call the Authorised Service Centre.
Call the Authorised Service Centre.
Call the Authorised Service Centre.
Call the Authorised Service Centre.
Check that the pressure in the system is correct. See section 5. If this
fault persists, call the Authorised Service Centre.
Check that the pressure in the system is correct. See section 5. If this
fault persists, call the Authorised Service Centre.
Call the Authorised Service Centre.
Press
OK
. If this fault occurs repeatedly, call the authorised service
centre.
Press
OK
. If this fault occurs repeatedly, call the authorised service
centre.
Call the Authorised Service Centre.
Call the Authorised Service Centre.
Call the Authorised Service Centre.
2 seconds