Table of burner pressures
240 Fi - 1.240 Fi
240 i - 1.240 i
310 Fi - 1.310 Fi
Gas used
G20
G31
G20
G31
G20
G31
injector diameter (mm)
1,18
0,74
1,18
0,74 1,28
0,77
Burner pressure (mbar*)
REDUCED HEAT OUTPUT
1,9
4,9
1,9
4,7
1,8
4,9
Burner pressure (mbar*)
/0.*/"-)&"5065165
11,3
29,4
10,0
26,0
13,0
35,5
no. of injectors
15
* 1 mbar = 10,197 mm H
2
O
Table 1
240 Fi - 1.240 Fi
240 i - 1.240 i
310 Fi - 1.310 Fi
Gas consumption at 15 °C - 1013 mbar
G20
G31
G20
G31 G20
G31
Nominal heat output
2,84 m
3
/h
2,09 kg/h
2,78 m
3
/h
2,04 kg/h
3,52 m
3
/h
2,59 kg/h
Reduced heat output
1,12 m
3
/h
0,82 kg/h
1,12 m
3
/h
0,82 kg/h
1,26 m
3
/h
0,92 kg/h
p.c.i.
34,02 MJ/m
3
46,3 MJ/kg
34,02 MJ/m
3
46,3 MJ/kg
34,02 MJ/m
3
46,3 MJ/kg
Table 2
19. PARAMETERS DISPLAY
19.1 INFORMATION AND ADVANCED SETTING MODE
To access the Information and Advanced Setting mode, it is necessary to press, for at least 3 seconds, the
IP
button; in
INFO mode the display shows
“INFO”
.
To escape the INFO mode briefly press the
IP
button. In this mode press the
OK
button to scroll the windows; to set
parameters press the
+/-
button.
WARNING
Communications between the main board and the remote control is not immediately. In some case it may hap-
pen that the command given through the remote control takes some time depending on the type of the tran-
sferred information.
$&/53"-)&"5*/( $)
r
i$)4-w
Max. heating circuit setpoint, value settable with the buttons
+/-
.
WARNING:
to change the unit of measure from °C to °F and vice versa, press the
button.
r
“EXT°c”
Outside temperature (with external sensor connected).
r
“CH O>”
Maximum Heating flow temperature.
r
“CH R<”
Return heating temperature (unplanned).
r
“CH S^”
CH temperature setpoint.
r
“CH MX”
Maximum CH temperature setpoint (max. settable value).
r
“CH MN”
Minimum CH temperature setpoint (min. settable value).
DOMESTIC HOT WATER (D.H.W.)
r
“HW O>”
D.H.W. flow temperature.
r
“HW S^ ”
Maximum setpoint temperature value setting. Press the
+/-
buttons to set the value.
r
“HW MX”
Maximum D.H.W. temperature setpoint (max. settable value).
r
“HW MN”
Minimum D.H.W. temperature setpoint (min. settable value).