Description of parameter
Default value
240 Fi
1. 240 Fi
240 i
1. 240 i
310 Fi
1.310 Fi
F01
Type of gas boiler
10
= sealed chamber -
20
= atmospheric chamber
10
20
10
F02
Type of gas
00
= natural (metane) -
01
= LPG
00 o 01
F03
Hydraulic system
00
= instantaneous appliance
05
= appliance with external water tank
08
= only heating appliance
00
08
00 08
00 08
F04
Programmable relay 1 setting
2
= zone system (See Service instructions)
02
F05
Programmable relay 2 setting
13
= Cool function (See Service instructions)
04
F06
External sensor programmable input setting
(See Service instructions)
00
F11…F12
Manufacture information
00
F13
CH max. heating output
(0-100%)
100
F14
D.H.W. max. heating output
(0-100%)
100
F15
CH min. heating output
(0-100%)
00
F16
Maximum temperature setpoint setting
00
= 85°C -
01
= 45°C
00
F17
Pump overrun time
(01-240 minutes)
03
F18
Minimum burner pause in central heating mode
(01-10 minutes) - 00=10 seconds
03
F19
Manufacture information
07
F20
Manufacture information
00
F21
Anti-legionella function
00
= Disabled -
01
= Enabled
00
F22
Manufacture information
00
F23
Maximum D.H.W. setpoint
60
F24
Not used
35
F25
Lack of water safety device
00
F26…F29
Manufacture information (only read parameters)
--
F30
Manufacture information
10
F31
Manufacture information
30
F32…F41
Diagnostics (See Service instructions)
--
-BTU
parameter
Controller stop function activation
(See Service instructions)
00
20. PARAMETERS SETTING
To access the Parameters setting mode proceed as follows:
r QSFTTGPSBUMFBTUTFDPOETUIF
IP
button;
r QSFTTàSTUUIF
button then press together the
button.
When the function is activated, the display shows “
F01
” with the value of the selected parameter.
Parameters setting
r 1SFTT
+/-
buttons for scrolling parameters;
r 1SFTT
+/-
buttons to change the single parameter value;
Nota
: the value is automatic saved after about 3 seconds.
(Do not press any button until the value is beginning to flash again).
0607_1908