17. REMOTE CONTROL INSTALLATION
5.
Fit the remote control inside the special housing on the front control panel without forcing;
6.
close the casing and fix it to the boiler with the screws (figure 11).
WARNING:
the remote control is a Low Tension appliance. Do not connect it to a 230 V power supply. For the electrical
connection refer to section 27 and 32.
PARAMETER SETTING
rTFUCPUIi
.0%6-
” and “
AMBON
” parameters = 0, as described in section 19.1;
rTFUQBSBNFUFS
F10 = 02
as described in section 20.
ROOM THERMOSTAT CONNECTION
r"DDFTTUIFQPXFSTVQQMZUFSNJOBMCMPDL àHVSF
rDPOOFDUUIFSPPNUIFSNPTUBUDBCMFTUPUFSNJOBMT F
rQSPWJEFQPXFSTVQQMZUPUIFCPJMFS
WARNING
If the ambient thermostat is not used, jump terminals
1-2
on the
M1
terminal block (figure 10).
To fit the remote control inside the boiler front control panel, proceed as
follows:
1.
Undo the two screws (
a-b
figure 11) fixing the casing to the boiler;
2.
Lift the casing slightly and with one hand push the front panel cover on
the outside (figure 11);
3.
Pass the red wire, coming from the terminal block
M2
(located behind
the casing), through the special hole in the remote control and cut it as
shown in figure 11.3)
4.
Open the remote control (there are no screws) by prising with hands and
connect the red wire (figure 11.3);
0606_0502
Figure 11
The remote control can be installed directly on the boiler or in the wall.
17.1 INSTALLING THE REMOTE CONTROL ON THE BOILER FRONT PANEL
0606_0503
0606_0504
Figure 11.1
Figure 11.2
Figure 11.3