Procedure of the commissioning
Instruction handbook
b maXX
(BM4-F-)AIO-XX (Analog IO module)
Document No.: 5.01045.08
Baumüller Nürnberg GmbH
56
8.2
Gain adjustment within the analog input link
Connection and measurement of a reference voltage (e.g. 9V monobloc battery)
Measured voltage (voltmeter): 9,235 V
Read value in ProDrive: 29295
Conversion of read value into voltage: =
=
Gain to be set
=
= 1,03
Check
Input short-circuited
⇒
No. of increments < 20
Connect voltage supply
Convert connected voltage to increments:
No. of increments =
The adjustment of an analog input channel of the AIO-01, AIO-02 and AIO-03 is complet-
ed now.
read value 10 V
⋅
32767
----------------------------------------------
29295 10
V
⋅
32767
-----------------------------------
8 940 V
,
=
connected (measured) voltage
read voltage
----------------------------------------------------------------------------------
9 235 V
,
8 940 V
,
----------------------
1 033
,
=
=
32767 connected (measured) voltage
⋅
10 V
------------------------------------------------------------------------------------------------------
32767 9 235 V
,
⋅
10 V
-------------------------------------------
30260
=
=