Procedure of the commissioning
Instruction handbook
b maXX
(BM4-F-)AIO-XX (Analog IO module)
Document No.: 5.01045.08
Baumüller Nürnberg GmbH
46
8.2
4
Choose submenu „Service“
This window shows the position/slot of the recognized
Analog IO module
.
If the
Analog IO module
is available in position/slot D, then the following is displayed:
„Slot D Analog IO 16 Bit Version X“.
„X“ shows the version of the module.
Always available with the ES controller is the module AIO-01 (position E), a further
AIO-02/03/04 can be used additionally.
5
Decide on the basis of the display:
Figure 11:
ProDrive Service
m
If the
Analog IO module
has been correctly recognized, the commissioning can be
continued, refer to Instruction Handbook b maXX 4000, 5.12008 or Parameter Man-
ual b maXX 4000, 5.03039.
m
If the
Analog IO module
has not been correctly recognized, turn off the device,
check the mounting and the installation. After removing all errors, switch on the de-
vice again.
m
If the
Analog IO module
has not been correctly recognized again, it is defect or the
controller/controller slot (of standard controller) is defect. Contact Baumüller Nürn-
berg GmbH for replacement.