Baumer Hübner
Disassembly
|
7
V1, T1 | HMG10 & HMG10P SSI
Operating Manual
41
7
Disassembly
NOTICE
Equipment damage due to mechanical shock
Strong vibration may lead to overload by constraining force.
a) Never apply force. If properly assembled, everything fits smoothly together.
b) Use only suitable tools for disassembly (see chapter on disassembly).
NOTICE
Equipment damage by adhering liquids
Sticky liquids may damage sensing unit and ball bearings. Disassembling a device which is
stuck to the axis can lead to destruction.
a) Do not use adhesive liquids to fasten the device.
NOTICE
The device can be easily removed via the cheese-had screw (M8x45 mm, ISO 4762) and
threaded pin (M6x10 mm, ISO 7436).
7.1
Removing the encoder from blind hollow shafts or cone shafts
DANGER
Burns caused by heat
The device heats up at high torque. There is a risk of getting burned after use.
a) Avoid overheating the device.
b) Wear suitable gloves.