5
|
Installation
Baumer Hübner
18
Operating Manual
HMG10 & HMG10P SSI | V1, T1
1
2
3
16
14
15
10
7
5
4
9
8
12
6
13
11
1
Blind hollow shaft or cone shaft with
wrench flat SW 17 mm
2
Cover
3
Torx/slotted head screw M4x10 mm (DIN
7964)
4
Cheese-head screw M6x30 mm (ISO
4762)
5
Spring washer 6 (DIN 7980)
6
Self-locking nut M6 (ISO 10511)
7
Torque arm
8
Washer B6.4 (ISO 7090)
9
Cheese-head screw M6x8 mm for
grounding strap (ISO 1207)
10
Washer B6.4 for grounding strap (ISO
7090)
11
Washer B6.4 (ISO 7090)
12
Washer B6.4 (ISO 7090)
13
Self-locking nut M6 (ISO 10511)
14
Grounding strap
15
Threaded rod M6 (variable length ≤ 210
mm)
16
Self-locking nut M6 (ISO 10511)
Tool
n
5 mm
n
10 mm, 17 mm
n
20 mm
n
1,6×8 mm
n
Measuring gauge
Instruction:
a) Verify drive shaft about any concentricity error (see further links).
b) Mount the encoder in a way ensuring the electrical connection is protected against water
ingress.
c) Loosen the encoder cover.
d) Apply grease onto the drive shaft.
e) Mount the encoder using cheese-head screw and spring washer. For doing so, tighten the
screw with a torque of 3-4 Nm and secure with wrench if necessary.