No.
LED
Description
1
GLUE
Status indicator for adhesive moni-
toring
2
OBJECT
Status indicator for product detec-
tion
3
READY
Status indicator for the sensor
7.1.1.1
Sensor programming
The sensor must be set up in the system control. Depending on the
control system, most of the settings can be programmed.
Information on sensor settings can be found in the operating
manual for the system control.
The following settings can be configured during programming:
n
Sensor offset value
n
Product detection sensitivity
n
Adhesive detection sensitivity
Depending on the application and the configuration of
the system, further settings may be necessary.
The status indicator for the sensor shows the status of the sensor
programming with the 3 LEDs.
n
Manual programming
n
Automatic programming
“Automatic programming (3 products with adhesive applica-
Programming
LED
Meaning
READY
OBJECT
GLUE
FLASHING
(alternating
green/blue)
FLASHING
(alternating
green/blue)
Off
A product without adhesive application was suc-
cessfully programmed.
FLASHING
(alternating red/
blue)
FLASHING
(alternating red/
blue)
Off
Programming process for a product without adhe-
sive application was unsuccessful.
Operation
Operation ULT 400 XL > Sensor ULT 400 XL
04.05.2021
ULT 400 XL
38