4.
Ensure that the bottom edge of the sensor housing is
62,5 mm ± 12,5 mm from the adhesive track.
5.
Make sure that the sensor is tilted by a maximum of 20° to
the adhesive track of the product.
6.
Check whether the light spot of the sensor is always on the
adhesive track to be monitored when the machine is running.
Correct the sensor’s position as necessary.
7.
Connect the sensor electrically.
“Electrical connection” on page 33
ð
The sensor has now been installed.
5.2 Electrical connection ULT 400 XL
5.2.1 Sensor ULT 400 XL
Personnel:
n
Qualified electrician
Protective equipment:
n
Protective work clothing
n
Safety boots
DANGER!
Risk of injury when entering the operating space of
the super-ordinate machine and its moving parts
CAUTION!
Risk of injury due to improper assembly and instal-
lation
WARNING!
Risk of personal injury or property damage due
electric current
Assembly and installation
Electrical connection ULT 400 XL > Sensor ULT 400 XL
04.05.2021
ULT 400 XL
33