1.
Make sure you have a Type A to B USB cable available for
connection.
2.
Connect Port A of the USB cable to a free USB port on the
PC.
3.
Screw the ring fitting on the display of the flow sensor.
4.
Pull the housing cap off the display of the flow sensor.
ð
The USB Port B of the flow sensor is freely accessible.
5.
Connect Port B of the USB cable to the USB port of the flow
sensor.
ð
The flow sensor is connected to the PC via USB.
n
The BCP software can be installed on the PC with all
drivers.
6.2 “BCP software installation” on page 45
n
The flow sensor can be configured.
6.2 BCP software installation
Personnel:
n
Operator
The flow sensor must be connected to a PC via the USB port.
The PC must have a functioning Internet connection to install the
BCP software with all drivers.
6.1 “Create USB interface” on page 44
1
Ring fitting
2
Housing cover
Commissioning
BCP software installation
12.08.2020
CombiFlow PF75H/S