39
Operating
pressure gas
Rate
Diameter
injector
Heat Input
(W)
By-Pass
Burner
mbar g/h L/h
1/100mm Min Max 1/100mm
G30 -
Butane
28 -
30
218 N/A
88 800
3000
G31 -
Propane
37 214 N/A
88 800
3000
Rapid
G20 -
Natural
20 N/A 286
117 - Y
800
3000
44
G30 -
Butane
28 -
30
131 N/A
68 600
1800
G31 -
Propane
37 129 N/A
68 600
1800
Semi -
rapid
G20 -
Natural
20 N/A 171
98 - Z
600
1800
34
G30 -
Butane
28 -
30
73 N/A
51 400
1000
G31 -
Propane
37 71 N/A
51 400
1000
Auxiliary
G20 -
Natural
20 N/A
95
75 - X
400
1000
28
G30 -
Butane
28 -
30
276 N/A
98 1400
3800
G31 -
Propane
37 272 N/A
98 1400
3800
Triple
Crown
G20 -
Natural
20 N/A 362
135 - K
1400 3800
62
o
Reassemble all the burners carefully; in particular you should
make sure that the flame spreader is correctly placed on the
burner.
IMPORTANT: After changing the injectors YOU MUST follow the
minimum flow adjustment section below.
Minimum flow adjustment for hob gas taps.
All work must be carried out by a GASSAFE
registered engineer.
o
Light the burner and set the knob at the
minimum position.
o
Remove the knob from the tap. The adjustment
screw is located beside the valve body.
o
Place a small bladed screwdriver in the centre
of the tap shaft.
o
Unscrew the adjusting screw, in order to
increase the gas flow or tighten the adjusting
screw to decrease the gas flow.
Содержание BCD901SS