TECHNICAL INFORMATION FOR

INSTALLATION PERSONNEL

T

his  appliance  shall  be  installed  only

by

 

authorised  personnel  and  in  accordance 

with

 

the  manufacturer’s  installation 

instructions,

 

local  gas  fitting  regulations, 

municipal  codes,

 

electrical  wiring  regulations, 

AS  5601/AG  601-Gas  Installation  and  any 
other  statutory

 

regulations.  Ventilation  must 

be  in  accordance

 

with  AS  5601/AG  601-  Gas

Installation.  In  general,  the  appliance  should
have  adequate  ventilation  for  complete
combustion  of  gas,  proper  flueing  and  to
maintain 

temperature 

of 

immediate

surroundings  within  safe  limits.  The  wall  and
bench  surfaces  must  be  capable  of  sustaining
temperatures of 75 °C.

All  laminates,  fixing  adhesive  and  surfacing
materials  should  be  certified  suitable  for  this
temperature.

Any  adjoining  wall  surface  situated  within  200  mm
from the edge of any hob burner must be a suitable
non-combustible material for a height of 150 mm for
the  entire  length  of  the  hob.  Any  combustible
construction  above  the  hotplate  must  be  at  least
650  mm  above  the  top  of  the  burner  and  no

construction  shall  be  within  450  mm  above  the  top
of  the  burner. A  minimum  depth  of  70  mm  from  the
top of the worktop surface must be provided for the
appliance.

In  line  with  Australian  regulations  A  bottom  part  of 

the rangehood can be installed at 600mm from the 

hihgest point of the gas cooktop.

3) INSTALLING THE HOT PLATE

Check that the appliance is in a good condition after
having  removed  the  outer  packaging  and  internal
wrappings  from  around  the  various  loose  parts.  In
case of doubt, do not use the appliance and contact
qualified personnel.

Never  leave  the  packaging  materials  (cardboard,
bags, polystyrene foam, nails, etc.) within children’s
reach since they could become potential sources of
danger.

The measurements of the opening made in the top
of the modular cabinet and into which the hot plate
will be installed are indicated in fig. 7.
Always comply with the measurements given for the
hole  into  w

h

ich  the  appliance  will  be  recessed

(see

 

fig. 7 and 8).

The  appliance  belongs  to  class  3  and  is  therefore
subject  to  all  the  provisions  established  by  the
provisions governing such appliances.

INSTALLATION

COMPLY WITH THE DIMENSIONS

Overall Dimensions 4F: 580 x 500  mm

Overall Dimensions 5F: 860 x 500  mm

FIG. 7

FIG. 8

A

B

C

D

E

4F (580)

553

473

63.5

63.5 100 min.

5F (860)

833

475

62.5

62.5 73.5 min.

Содержание B6FS

Страница 1: ......

Страница 2: ...ry a complete range of spare parts for all Home Appliance products For all your spare parts enquiries please contact our After Sales Support team on 1800 444 357 and Select 2 IMPORTANT To assist in ha...

Страница 3: ...burner 5 Cast iron pan support for ultra rapid burner 6 Cast iron pan support 2F right 7 Cast iron pan support 2F left 8 Burner n 1 control knob 9 Burner n 2 control knob 10 Burner n 3 control knob 11...

Страница 4: ...h 11 4 MJ h 22 24 Rapid 12 0 MJ h 10 4 MJ h 20 22 Semi rapid 7 1 MJ h 6 3 MJ h 16 18 Auxiliary 4 1 MJ h 3 6 MJ h 10 14 Burners with flame failure device may only be ignited when the relative knob has...

Страница 5: ...ous parts harmless especially for children who might play on an abandoned appliance Do not touch the appliance with wet or damp hands or feet Do not use the appliance barefoot The manufacturer will no...

Страница 6: ...n the burner head It must be steady The exact position of the pan support is established by the rounded corners which should be set towards the side edge of the hot plate Do not force the taps if they...

Страница 7: ...e within 450 mm above the top of the burner A minimum depth of 70 mm from the top of the worktop surface must be provided for the appliance In line with Australian regulations A bottom part of the ran...

Страница 8: ...be used provided it is capable of withstanding the appliance temperatures Ensure that the supply connection point is accessible with the appliance installed To facilitate the shield may need to be rem...

Страница 9: ...ittings must be used and all connections tested for gas leaks The gas supply connection point must be accessible with the appliance installed Natural Gas Natural Gas installations require the connecti...

Страница 10: ...e is connected to the electricity main by a socket Fit a standard plug suited to the load indicated on the data label to the cable Fit the wires following figure n 13 taking care of respecting the fol...

Страница 11: ...iance fails to operate correctly after all checks have been carried out refer to the authorised service provider in your area 7 TAPS Our taps are suitable for all the gas they are male conical type at...

Страница 12: ...r the gas connection 12 Fit the new data label included in the gas conversion kit 9 NATURAL GAS TO U LPG GAS CONVERSION PROCEDURE Appliance models Gas stainless steel hotplate models 4 Burners 5 Burne...

Страница 13: ...tops using a wrench B Now unscrew injector A see fig 15 15 A and fit a injector corresponding to the utilized type of gas in its place It is advisable to strongly tighten the injector in place After...

Страница 14: ...LE SINGLE PHASE POWER SUPPLY Gas hot plate H05 RR F Section 3 x 0 75 mm 2 If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person i n...

Страница 15: ...ents are required specifying the type of fault and the model of the appliance in your possession Please also note that genuine spare parts are only available from our After Sales Service Centers and a...

Страница 16: ......

Отзывы: