background image

INSTALLATION

10

6) ELECTRICAL CONNECTION

The appliance is supplied with flexible supply lead.
The point of attachment for this lead is located at the
rear  and  on  the  underside  of  the  appliance
380 mm from the right hand side.
The voltage and power consumption are detailed on
the  underside  of  the  appliance.  Ensure  that  the
appliance is correctly rated to the supply.
Connect appliance by way of a switched power point
.

THE APPLIANCE MUST BE EARTHED 

Ensure  that  this  power  point  is  properly  earthed.
Look  at  the  connection  wiring  diagrams 
(fig. 13/A and 13/B).

Warning:  in  order  to  avoid  any  hazard,  any
electrical  work  performed  on  this  equipment  or
its  associated  wiring,  should  only  be  done  by
persons  a  qualified by  the  supplier  or  similarly
qualified persons.
The  socket  outlet  for  this  hotplate  shall  be
installed  near  the  hotplate  and  shall  be  easily
accessible.
The electrical connections of the appliance must
be carried out in compliance with the provisions
and standards in force.

Before connecting the appliance, check that:
- The  voltage  matches  the  value  shown  on  the

specification  plate  and  the  section  of  the  wires  of
the electrical system can support the load, which is
also indicated on the specification plate.

- The  electrical  capacity  of  the  mains  supply  and

current  sockets  suit  the  maximum  power  rating  of
the appliance (consult the data label applied to the
underside of the hotplate).

- The  socket  or  system  has  an  efficient  earth

connection  in  compliance  with  the  provisions  and
standards  in  force.  The  manufacturer  declines  all
responsibility  for  failing  to  comply  with  these
provisions.

When  the  appliance  is  connected  to  the
electricity main by a socket:

- Fit  a  standard  plug  suited  to  the  load  indicated  on

the data label to the cable.

- Fit the wires following figure n.13 taking care of

respecting the following correspondences:

Letter L (live) = brown wire;

Letter N (neutral) = blue wire;

Earth symbol 

= green - yellow wire.

- The power supply cable must be positioned so that no

part of it is able to reach an overtemperature of 90 °C.

- Never  use  reductions,  adapters  of  shunts  for

connection since these could create false contacts
and lead to dangerous overheating.

When  the  appliance  is  connected  straight  to  the
electricity main:

- Install  an  omnipolar  circuit-breaker  between  the

appliance  and  the  electricity  main.  This  circuit-
breaker  should  be  sized  according  to  the  load
rating  of  the  appliance  and  possess  a  minimum  3
mm gap between its contacts.

- Remember  that  the  earth  wire  must  not  be

interrupted by the circuit-breaker.

-The  electrical  connection  may  also  be  protected  by

a high sensitivity differential circuit- breaker.

You  are  strongly  advised  to  fix  the  relative  yellow-
green earth wire to an efficient earthing system.

Before  performing  any  service  on  the  electrical
part  of  the  appliance,  it  must  absolutely  be
disconnected from the electrical network.

IMPORTANT: the appliance must be installed
following the manufacturer's instructions. The
manufacturer will not be liable for injury to
persons or animals or property damage caused
by an incorrect installation.

If  the  installation  requires  modifications  to
the  home's  electrical  system  or  if  the
socket is incompatible with the appliance's
plug,  have  changes  or  replacements
performed  by  professionally-qualified
person. In particular, this person must also
make  sure  that  the  section  of  the  wires  of
the  socket  is  suitable  for  the  power
absorbed by the appliance.

FIG. 13

Содержание B6FS

Страница 1: ......

Страница 2: ...ry a complete range of spare parts for all Home Appliance products For all your spare parts enquiries please contact our After Sales Support team on 1800 444 357 and Select 2 IMPORTANT To assist in ha...

Страница 3: ...burner 5 Cast iron pan support for ultra rapid burner 6 Cast iron pan support 2F right 7 Cast iron pan support 2F left 8 Burner n 1 control knob 9 Burner n 2 control knob 10 Burner n 3 control knob 11...

Страница 4: ...h 11 4 MJ h 22 24 Rapid 12 0 MJ h 10 4 MJ h 20 22 Semi rapid 7 1 MJ h 6 3 MJ h 16 18 Auxiliary 4 1 MJ h 3 6 MJ h 10 14 Burners with flame failure device may only be ignited when the relative knob has...

Страница 5: ...ous parts harmless especially for children who might play on an abandoned appliance Do not touch the appliance with wet or damp hands or feet Do not use the appliance barefoot The manufacturer will no...

Страница 6: ...n the burner head It must be steady The exact position of the pan support is established by the rounded corners which should be set towards the side edge of the hot plate Do not force the taps if they...

Страница 7: ...e within 450 mm above the top of the burner A minimum depth of 70 mm from the top of the worktop surface must be provided for the appliance In line with Australian regulations A bottom part of the ran...

Страница 8: ...be used provided it is capable of withstanding the appliance temperatures Ensure that the supply connection point is accessible with the appliance installed To facilitate the shield may need to be rem...

Страница 9: ...ittings must be used and all connections tested for gas leaks The gas supply connection point must be accessible with the appliance installed Natural Gas Natural Gas installations require the connecti...

Страница 10: ...e is connected to the electricity main by a socket Fit a standard plug suited to the load indicated on the data label to the cable Fit the wires following figure n 13 taking care of respecting the fol...

Страница 11: ...iance fails to operate correctly after all checks have been carried out refer to the authorised service provider in your area 7 TAPS Our taps are suitable for all the gas they are male conical type at...

Страница 12: ...r the gas connection 12 Fit the new data label included in the gas conversion kit 9 NATURAL GAS TO U LPG GAS CONVERSION PROCEDURE Appliance models Gas stainless steel hotplate models 4 Burners 5 Burne...

Страница 13: ...tops using a wrench B Now unscrew injector A see fig 15 15 A and fit a injector corresponding to the utilized type of gas in its place It is advisable to strongly tighten the injector in place After...

Страница 14: ...LE SINGLE PHASE POWER SUPPLY Gas hot plate H05 RR F Section 3 x 0 75 mm 2 If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person i n...

Страница 15: ...ents are required specifying the type of fault and the model of the appliance in your possession Please also note that genuine spare parts are only available from our After Sales Service Centers and a...

Страница 16: ......

Отзывы: