38
6.11.1 SOLAR PANEL
In the factory a solar panel is mounted which is maintenance free.
1. In order to ensure optimal performance the surface should be cleaned from time to time with a soft cloth and
household cleaning agent ( no scrubbing agent).
2. For operation the solar panel is unfolded and blocked. The solar radiation on the panel is more intensive.
For transport of the RAINSTAR the panel is folded again. It is lifted and pressed to the machine and can be
brought into its initial position where it is protected against damage.
3. In order to prevent over charging of the accumulator battery and a disturbance of the ECOSTAR, the electronic
interrupts the charging process if the „STOP“ key is pressed or the accumulator battery is connected (When the
machine is delivered the clamps are removed)
6.11.2 CHECKING THE CONNECTIONS
Press „START“ key.
The regulating motor closes(the segment turns to the limiting bolt)
The shut-off valve overpressure opens.
The shut-off valve low pressure remains closed.
Press „STOP“ key
The regulating motor opens the turbine (the segment turns away from the limiting bolt)
The shut-off valve overpressure closes
The shut-off valve low pressure opens
6.11.3 CHECKING THE LENGTH SENSOR
The magnet disc with 4 magnets is mounted on the drive shaft of the gear and rotates clockwise during retraction.
By rotating the magnet disc clockwise the display for the laid down pipe needs to count from 0 m upwards.
If the distance counter counts into the opposite direction then the speed sensor must be turned around in order that
the cable connection is on top. Distance 1 - 3 mm between double sensor and magnet disc.
Speed sensor
Cable connection at the
bottom