background image

PNEUMATIC ZEUS mod. 2009 

page 5 

January 2009 

 

Signals that the maximum number of hours set for the cleaning of the boiler’s 

probe  has  been  exceeded.  Clean  the  probe  and  reset  the  warning  (see 
CLEANING OF PROBE - SET & RESET ).

 

 

Signals an anomalous overheating  of the boiler. The type of warning can be 
read  on  the  display.  WARNING:  a  safety device  will  block  the heating  of  the 

water inside the boiler or the heating of the super-heater. Turn off  the main 

switch and wait for half an hour. If the problem reoccurs, contact Authorized 
Service Centre.  

 

 
 

8.

 

CONNECTION AND STARTING 

 

1.

 

Place ZEUS on a plain clean floor, at least 2 metres far from other appliances, from 
metal-enclosed bus ducts and from electric or electronic parts. 

2.

 

Connect the water rubber hose to the ZEUS hose holder called WATER INLET 

(fig. 

1)

 and turn the water tap. 

3.

 

Connect the power supply cable to a grounded outlet, with observance of the law 

in force and a voltage suitable to ZEUS. 

4.

 

Connect  the  compressed  air  tube  to  the  pressure  adapter  and  adjust  it  to  a 

maximum pressure of  6 bar 

(fig. 6)

5.

 

Turn  on  the  main  switch  and  the  electronic  card  (see  key  table).  Select  which 

functions  are  to  be  activated  and  which  to  be  deactivated  (clamps,  boiler,  …).  If 

the main switch is turned off the functions previously set will be memorized so that 
they will automatically be activated once the machine is switched on again. 

 

 

 
9.

 

SET e RESET 

 

To  gain  access  to  the  SET  menu,  the  electronic  card  must  be  in 

stand-by

 

mode. Press the key shown on the left. To exit the SET mode, press the key 

once again or wait for 5 seconds.  

 

SET menu:  

 

HOURS OF WORK 

OK

 

°C

UP

DOWN

 

TOTAL HOURS: 

 

To exit 

ESC

 

PARTIAL HOURS: 

Reset 

OK

RESET

OK

 

 

TOTAL HOURS: computation of the total hours the machine has worked for. This data 

cannot be zeroed.  
PARTIAL HOURS: computation of the hours the machine has worked for since the last 

zeroing. This data can be zeroed (see table). 

SET

 

Содержание PNEUMATIC ZEUS/A

Страница 1: ...ATIC ZEUS A mod 2009 POWER SUPPLY V 400 NEUTRAL TOTAL INSTALLED POWER W 11850 BOILER POWER W 9000 VACUUM BLOWING MOTOR POWER HP 1 75 HZ 50 PUMP POWER HP 0 8 HZ 50 BOILER CAPACITY L 10 IRONING ENDURANC...

Страница 2: ...s in stand by mode red led on This mode allows access to the SET menu in order to set functions such as language periodical maintenance warnings etc see point 6 Electronic card in stand by mode If mai...

Страница 3: ...m phase timing increase decrease keys Timing may be set from 0 to 99 seconds Air steam phase timing increase decrease keys Timing may be set from 0 to 99 seconds RESET Air phase timing increase decrea...

Страница 4: ...time Check that water comes out of the pipe connected to the water supply Turn off the main switch wait for 5 seconds and turn the machine on again If the problem reoccurs contact Authorized Service...

Страница 5: ...supply cable to a grounded outlet with observance of the law in force and a voltage suitable to ZEUS 4 Connect the compressed air tube to the pressure adapter and adjust it to a maximum pressure of 6...

Страница 6: ...ed Manufacturer authorized access only WARNING AFTER 10 ATTEMPTS TO ACCESS THE MAINTENANCE OR MANUFACTURER MENU WITHOUT TYPING IN THE PASSWORD AND OR BY TYPING THE WRONG PASSWORD THE SET MENU WILL BE...

Страница 7: ...by grasping the handle and pulling the racket with one s thumb fig 3 In addition by turning the handle clockwise or anticlockwise you can adjust the pressure exerted by the paddle on the garment prev...

Страница 8: ...ps too much a high pressure might cause hand injuries if accidentally pressed by the clamps Should it occur push immediately on the opening button fig 2 15 ADJUSTMENT OF OPENING AND CLOSING SPEED OF A...

Страница 9: ...he values stored by the manufacturer will be set According to the ironing program chosen the suggested air adjustment will be displayed Fig 1 Example KINTTED LADIES DRESS air adj 1 N B the setting of...

Страница 10: ...of arms and clamps Note 1 it is possible to interrupt the working cycle anytime by pressing the pedal 2 each time you change the type of fabric to iron and especially when changing from heavy fabrics...

Страница 11: ...or the operator 1 damaging of electrical cables of the iron 2 the earth protector switch is activated when switching on the main switch 3 using ZEUS during thunderstorms 4 using ZEUS without proper pr...

Страница 12: ...3 For six monthly cleaning of ZEUS follow these instructions open the side and back panels clean the inner part with compressed air with special care to the ventilator fan of the blowing motor 4 Chec...

Страница 13: ...he power current fuses see SUBSTITUTION OF POWER CURRENT FUSES To restart the machine do as follows set the main switch on position 0 unscrew the 4 screws of the panel find the motor protector and res...

Страница 14: ...uses the main switch must be on pos 0 and the four screws are to be unscrewed from the panel N B SUBSTITUTE FUSES WITH INTERCHANGEABLE ONES AND WITH THE SAME PERFORMANCE 29 COMPULSORY AND PERIODICAL M...

Страница 15: ...disposal and recycling of the machine s components assures protection of the natural environment Every product manufactured by BATTISTELLA B G S r l is subject to following limitations Battistella B...

Отзывы: