14
Rev. 3.1 (08.2020)
1 Änderungen vorbehalten
If the pump should be removed again, the Molex connector needs to be opened before removal!
In order to prevent damage to the flexible cable, the following points should be considered for the final pump
assembly:
-
the flexible connector must not be bent around sharp edges or kinked
-
the flexible connector must not be bend on top or bottom of the pump
-
the Molex connector is not water tight, additional sealing with e.g. silicone will be necessary
-
fixation of the Molex connector in the final assembly is recommended
The Molex flex cable has contacts only on one side, so it can be connected to the Molex connector only in one way.
If connected in the other way, the pump will not function.
Cleaning the system
The pump can be washed with water, alcohol (isopropanol) or if necessary with weak acid by pumping or by flushing
with the help of a syringe.
Flushing is only possible in pump direction!