background image

3

 

Rev. 3.1 (08.2020)   

 

        

 

General 

This  operating  manual  contains  all  necessary  instructions  for  the  installation,  commissioning,  operation  and 
maintenance of the mp6-series. The manual is intended to help you achieving optimal results in a short time and 
shall also assist avoiding possible sources of errors. The operating manual of the controllers and the accessories are 
available separately. 

The  products  have  been  designed  with  state-of-the-art  technology  and  in  accordance  with  all  relevant  safety 
regulations. However, a risk of damage to the units, other property, the operator and/or other persons cannot be fully 
excluded.  
Always ensure that specialized and trained personnel will comply with the following general instructions. Therefore, 
please keep this manual and hand out copies as required. 
Bartels  Mikrotechnik  GmbH  rejects  any  responsibility  for  damages  to  persons  or  property  resulting  from  non-
compliance with the instructions in this manual. In this case all warranties shall be void. 

Declaration of conformity 

Bartels  Mikrotechnik  GmbH  declares  that  the  products  are  compliant  to  the  RoHS  directive  2011/65/EU.  The 
controllers comply with the requirements of EMV 2014/30/EU and CE markings have been affixed to the devices. 
Additionally, the controllers are also compliant to the EU Low Voltage Directive 2014/35/EU. 

Description of functions 

The micropumps have been developed for the transport of gases or liquids. The controllers have been developed for 
operating the micropumps. Bartels Mikrotechnik can assume no liability for damages resulting from the pump media. 
This applies especially for hazardous fluids. 
The pumps must be operated with Bartels Mikrotechnik electronics. Bartels Mikrotechnik GmbH cannot guarantee 
the  proper  work  of  the  units  with  customer  specific  electronics.  If  other  controllers  than  the  ones  from  Bartels 
Mikrotechnik are used, Bartels Mikrotechnik disclaims any warranty. 

Moreover, please note that components of the controller and pump are operating with high-voltage.

 Therefore, 

persons wearing pacemakers are recommended to avoid the operating system. 
Bartels Mikrotechnik assumes no liability for abnormal handling, improper or negligent use of the micropump and 
the  controller  that  is  not  conform  to the  specified  purpose  of  the  system.  This  applies  especially  for  micropump 
controllers, components and systems of other manufacturers, which have not been certified by Bartels Mikrotechnik.

 

We guarantee that the micropumps comply with the actual state of scientific and technical knowledge and due to 
this, the operational risks are limited to a minimum.  

Do not open the housing of the micropump and the controllers.

 In those cases, Bartels Mikrotechnik cannot issue 

a guaranty anymore. Please keep this manual safe and give a copy to all users. 

 

 

Содержание microComponents mp6-gas

Страница 1: ...1 Rev 3 1 08 2020 Operating Manual for Micropump mp6 series...

Страница 2: ...specifications 5 Technical Data of the mp6 hyb1 5 Technical Data of the mp6 liq1 2 6 Technical specifications mp6 pi1 7 Technical specifications mp6 pp1 9 Technical specifications mp6 gas1 10 Final in...

Страница 3: ...Low Voltage Directive 2014 35 EU Description of functions The micropumps have been developed for the transport of gases or liquids The controllers have been developed for operating the micropumps Bar...

Страница 4: ...ditions including vapors is not permitted Staff selection and qualification All work in connection with the installation assembly commissioning decommissioning disassembly operation servicing cleaning...

Страница 5: ...in typ flow rate p 0 8 ml min 4 typ back pressure p 0 500 mbar 7 25 psi 4 Gases air typ volume flow p 0 20 ml min 5 typ back pressure p 0 80 mbar 1 16 psi 5 1 Typical values Values can vary under appl...

Страница 6: ...Please contact us for more information Please find more information concerning the controller and the equipment in the corresponding manuals mp6 liq Order code mp6 liq Pump type piezoelectric diaphrag...

Страница 7: ...1 1811 x 0 5906 x 0 1498 in Weight 2 g Fluidic connectors barbed tube clip outer diameter 1 9 mm length 3 5 mm 2 Electric connector flex connector 1 25 mm pitch Power consumption 50 mW 5 Self priming...

Страница 8: ...Tygon tubing 1 3 mm inner diameter 3 Conditions Suction pressure 10 mbar DI water settings mp x 100 Hz 250 V SRS the max volume flow will be reached after a few minutes of operation time 4 Conditions...

Страница 9: ...ter Controllable flow range8 8 l min 4000 l min typ flow rate p 0 4 ml min 4 typ back pressure p 0 500 mbar 7 25 psi 4 1 Typical values Values can vary under application conditions Content is subject...

Страница 10: ...1498 in Weight 2 g Fluidic connectors barbed tube clip outer diameter 1 9 mm length 3 5 mm 2 Electric connector flex connector 1 25 mm pitch Power consumption 150 mW 5 Self priming yes 3 Pumping medi...

Страница 11: ...er 3 Conditions air room temperature 23 C settings mp x 300 Hz 250 V SRS the max volume flow will be reached after a few minutes of operation time 4 Conditions gases room temperature 23 C mp x 300 Hz...

Страница 12: ...rating the micropump In this chapter the operation of the micropump during the evaluation is described This chapter provides information on the proper connection of the pump with tubing and electrical...

Страница 13: ...mp6 series to the cable The pumps can be connected via a FCC connector The layout of the connector and pin assignment of the pumps is as shown below Each piezo P1 P2 has a single lead for the negative...

Страница 14: ...n top or bottom of the pump the Molex connector is not water tight additional sealing with e g silicone will be necessary fixation of the Molex connector in the final assembly is recommended The Molex...

Страница 15: ...neral for driving the pump with air the following points should be taken into account Higher frequencies should be used compared to pumping water Large amplitudes respectively driving voltages should...

Страница 16: ...uencies The performance depends on the environmental conditions Combination of micropumps The micropumps can be combined to achieve higher flow rates or pressure than the single unit can generate With...

Страница 17: ...l 49 231 47730 500 Fax 49 231 47730 501 Visit our Website www bartels mikrotechnik de for further information on applications Tutorials and helpful answers to frequently asked questions can be found i...

Отзывы: