11
Rev. 3.1 (08.2020)
Typical values of flow and back pressure for selected media
(values measured with mp-x: 300 Hz, 250 V, SRS):
Gases
typ. volume flow
𝑣̇
(p=0)
20 ml/min (300 Hz)
5
typ. back pressure p (
𝑣̇
=0)
100 mbar (300 Hz)
5, 8
1
Typical values. Values can vary under application conditions. Content is subject to changes without notice.
2
Recommended tubing: Tygon tubing 1.3 mm inner diameter.
3
Conditions: air, room temperature 23°C, settings mp-x: 300 Hz, 250 V, SRS, the max. volume flow will be reached after a few minutes of
operation time.
4
Conditions: gases, room temperature 23°C, mp-x: 300 Hz, 250 V, SRS
5
Conditions: settings mp-x: 300 Hz, 250 V, SRS
6
Can be changed to IP44.
7
For media compatibility details please find more information in the corresponding media compatibility sheets.
8
The mp6-gas is available as mp6-gas+ version with 150 mbar of back pressure.
Please find more information concerning the controller and the equipment in the corresponding manuals.