0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16 cm
21-1680-7D0001/A-05/11-BEH-D278564
EN 8/12
PSB
Installation instructions
1
Connection
The dimensions specified in the installation instructions must be
strictly observed!
Cut the heating tape with a straight cut.
Push on the cap for screw connection
a
and sealing
b
.
Remove 145 mm of the protective outer sheath from the heating
tape.
Push the protective braid back (1). Use the screwdriver to form an
eyelet (2). Be careful not to damage the internal insulation.
Pull the heating tape out of the protective braid (3).
2
145
Installation kit 05-0091-0129/05-0091-0135
a
b
c
d
e
f
g
h
Self-limiting parallel heating cable
2 3
4
5
1
wire
2 heating element
3 insulating jacket
4
metal braid covering
5 protective outer sheath
1
1
2
2
3
3