Operating instructions 

1. Product description

The  PSB  type  27-1680-..10/....  Ex  heating  system  with  the 
PSB (type 07-5801....) self-limiting parallel heating tape, assembled 
with a connection and remote end termination system (installation kit 
05-0091-0130 and/or 05-0091-0136) in cold connection technology, is 
set up as a stationary resistance heating system for pipelines or containers 
in hazardous areas. It is used in Zones 1, 2 or Zone 21 according to the 
certified explosion group II and temperature classes T5/T6. 

After assembly the supply wires and the twisted protective braid of the 
heating tape are always connected to terminals in an enclosure with 
„increased  safety“  protection  class  (in  conformance  to  the  relevant 
standards EN 60079-0 and EN 60079-7).

3.  Safety Instructions

The  relevant  installation  and  operating  regulations  must  be 
observed  for  electrical  systems  in  hazardous  areas  (e.g.  Directive 
1999/92/EC,  Directive  94/9EC,  EN  60079-14,  EN  61241-14  and  the 
DIN VDE 0100 series).

The  requirements  under  EN  60519-1  and  EN  60519-2  must  be  
adhered to.

Thermal Safety Class  0 under EN 60519-2 Section 13 is met by the heating 
tape’s design characteristics.

The Cu braid with a resistance of < 18.2 

/Km is suitable as a protective 

conductor.

To protect against indirect contact, conductive parts from other firms must 
be included in the (protective conductor) safety measures. For each electric 
circuit it is necessary to have a residual-current circuit-breaker and a 
means of isolating all outer wires from the current supply.

The operator of an electrical system in a hazardous environment has to 
keep the equipment in an orderly condition, operate it correctly, monitor 
it and do the required maintenance and repairs.

(EN 60079-14, EN 60079-17, EN 60079-19 and EN 61241-14). 

4.  Assembly of heating circuits

The  specifications  in  the  EC  Type  Examination  Certificate  and  in  the 
installation  instructions  must  be  observed.  The  data  in  Installation 
Instruction for the heating tape must be observed also.
Do not connect the heating tape’s two supply wires – short circuit! 

2.   Technical data

Rated voltage 
 

110 to 120 V or 208 to 254 V

Rated current 
 

 max. 32 A

Referenced rated capacity      
 

 max. 33 W/m at 10°C

 

 Explosion protection

Ex protection type  
 

  II 2G   Ex e II T5, T6 

 

  II 2D Ex tD A21 IP65 T 95 °C, T 80 °C

Certification        
 

KEMA 08 ATEX 0111 

 

IECEx KEM 09.0084

Conformity to standards:       
 

EN 60079-0: 2006, EN 60079-7: 2007, EN 60079-30-1:  

 

2007, EN 61241-0: 2006, EN 61241-1: 2004

Minimum bending radius       
 

 25 mm

Max. permissible process temperature 
(applies to heating tape with remote end termination) 
 

 +65°C when the heating tape is switched on 

 

 +80°C when the heating tape is switched off 

 

cumulative 1,000 h

Ambient temperature range 
 

 -55°C to +55°C

Min. cut-in temperature 
 

-40 °C

5.a) Assembly 

The relevant installation and operating regulations must be observed when 
setting up or operating explosion-protected systems (e.g. EN60079-14, 
EN 60079-30-2 and the DIN VDE 0100 series).

The heating tape must be installed on the workpiece in accordance with 
the project engineering specifications. Only qualified specialists may do 
any of the work on the machine. Before any work is done on the machine, 
it must have come to a complete stop, be disconnected and precautions 
must be taken to ensure that it cannot be switched on again.

Before and during installation: keep the ends and connection components 
of the heating system dry. The metallic braiding in this heating system 
must be connected to a suitable earthing terminal.

!! The bending radius may not be less than the minimum of 25 mm and 
the heating tape may not be bent on its narrow side. 

The heating tape is attached to the workpiece by means of temperature-
resistant  adhesive  tape  with  a  max.  spacing  of  200  mm!!  Use  only 
plasticiser-free adhesive tapes (no PVC adhesive tapes)!

To ensure efficient heat transmission, the heating tape must have even 
contact over the entire length of the surface. If necessary, the distances 
between fastenings must be reduced. The tape is laid on 

Reservation

Technical data subject to change without notice. Changes, errors and misprints may not be used as a basis for any claim for damages.

Содержание PSB 27-1680

Страница 1: ...PSB Aufkleber EN 1 12 Installation and Operation Connection and Remote End Termination for PSB Type 27 1680 10 heating system...

Страница 2: ...21 1680 7D0001 A 05 11 BEH D278564 EN 2 12...

Страница 3: ...must be observed also Do not connect the heating tape s two supply wires short circuit 2 Technical data Rated voltage 110 to 120 V or 208 to 254 V Rated current max 32 A Referenced rated capacity max...

Страница 4: ...missioning The equipment may only be operated if it is clean and free of any damage Electrical systems must be examined by an electrician before commissioning and afterwards at certain intervals of ti...

Страница 5: ...the basis of the table and points 1 6 The blanks in the heating system s type number must be filled on the basis of the components used A water proof and lightfast marker must be used e g Staedtler Lu...

Страница 6: ...compliance with EN 60079 7 must be presented for all components Requirements set for connecting terminals Rated cross section 6 mm Working temperature 55 C up to 80 C Minimum distance between conduct...

Страница 7: ...EN 7 12 Declaration of Conformity Reservation Technical data subject to change without notice Changes errors and misprints may not be used as a basis for any claim for damages...

Страница 8: ...onnection a and sealing b Remove 145 mm of the protective outer sheath from the heating tape Push the protective braid back 1 Use the screwdriver to form an eyelet 2 Be careful not to damage the inter...

Страница 9: ...he strands out and twist them Remove the remaining heating element Fig 7 and 8 7 Reservation Technical data subject to change without notice Changes errors and misprints may not be used as a basis for...

Страница 10: ...ating tape Take the metal braid covering off the end of the heating cable Make sure that the internal insulation is not damaged Cut out a triangle 5 mm between the strands Screw the screw connection b...

Страница 11: ...EN 11 12...

Страница 12: ...EN 4 12 Max Eyth Stra e 16 97980 Bad Mergentheim Phone 49 7931 597 0 Fax 49 7931 597 494 info bartec de www bartec group com BARTEC GmbH Germany 21 1680 7D0001 10 09 BEH D278564...

Отзывы: