Installation instructions

10

12

Remote end termination

13

Put silicone adhesive 

h

 into the end cap 

g

 and onto the exposed 

insulating jacket. Push the end cap over the end of the heating tape 
until some of the adhesive oozes out.

Cut off the heating tape with a straight cut. Remove 7 mm from the 
protective outer sheath on the heating tape.

Take the metal braid covering off the end of the heating cable. 
Make sure that the internal insulation is not damaged. Cut out a 
triangle (5 mm) between the strands.

Screw  the  screw  connection  body

  a

  in  the  enclosure.  

Push the grounding strap

 c

 over the thread and secure it with a nut

 

b

. Connect the green/yellow core wire of the grounding strap to the 

PE. Connect the heating tape in the junction box to L, N and PE, 
insert the heating tape with the pushed-on sealing into the screw 
connection body and tighten the screw cap. The grounding strap c 
is not needed for stainless steel or aluminium enclosures.

11

140

7

5

Содержание PSB 27-1680

Страница 1: ...PSB Aufkleber EN 1 12 Installation and Operation Connection and Remote End Termination for PSB Type 27 1680 10 heating system...

Страница 2: ...21 1680 7D0001 A 05 11 BEH D278564 EN 2 12...

Страница 3: ...must be observed also Do not connect the heating tape s two supply wires short circuit 2 Technical data Rated voltage 110 to 120 V or 208 to 254 V Rated current max 32 A Referenced rated capacity max...

Страница 4: ...missioning The equipment may only be operated if it is clean and free of any damage Electrical systems must be examined by an electrician before commissioning and afterwards at certain intervals of ti...

Страница 5: ...the basis of the table and points 1 6 The blanks in the heating system s type number must be filled on the basis of the components used A water proof and lightfast marker must be used e g Staedtler Lu...

Страница 6: ...compliance with EN 60079 7 must be presented for all components Requirements set for connecting terminals Rated cross section 6 mm Working temperature 55 C up to 80 C Minimum distance between conduct...

Страница 7: ...EN 7 12 Declaration of Conformity Reservation Technical data subject to change without notice Changes errors and misprints may not be used as a basis for any claim for damages...

Страница 8: ...onnection a and sealing b Remove 145 mm of the protective outer sheath from the heating tape Push the protective braid back 1 Use the screwdriver to form an eyelet 2 Be careful not to damage the inter...

Страница 9: ...he strands out and twist them Remove the remaining heating element Fig 7 and 8 7 Reservation Technical data subject to change without notice Changes errors and misprints may not be used as a basis for...

Страница 10: ...ating tape Take the metal braid covering off the end of the heating cable Make sure that the internal insulation is not damaged Cut out a triangle 5 mm between the strands Screw the screw connection b...

Страница 11: ...EN 11 12...

Страница 12: ...EN 4 12 Max Eyth Stra e 16 97980 Bad Mergentheim Phone 49 7931 597 0 Fax 49 7931 597 494 info bartec de www bartec group com BARTEC GmbH Germany 21 1680 7D0001 10 09 BEH D278564...

Отзывы: