MAK 3003 EASI Ultrasampler Controller Type 6970-31, Configuration, Software version EASI 1.00, SAK 200311
4.3.5
Basic Settings
Basic Settings
Filling control mode
Flow level meter:
current and voltage input
Milk sensor:
Via milk sensor and permanently configured
pump output.
Flow FLM at 4-20 mA
Flow rate at 20 mA expected by the sampler at the FLM power
input (Input in l/min)
Pump capacity
small amount
Average pumping (suction) rate for collection quantities that are
smaller than the quantity entered under “threshold small/medium
quantity”.
Flow (Input in l/min)
middle amount
Average pumping rate for collection quantities that lie between
“small/medium” and “medium/high” quantity entered under “thresh-
old quantity”.
Flow (Input in l/min)
high amount
Average pumping rate
for collection quantities that lie above “me-
dium/high” quantity entered under “threshold medium/high quan-
tity”.
Flow (Input in l/min)
post sucking
Flow during the suction period. (Input in l/min)
Sucking time
After the milk sensor M1 reports "empty", sucking will continue for
this period (s)
Switching threshold
The pumping rate to match the expected or preset quantity of milk is relayed to the
ULTRASAMPLER
®
.
small/medium quantity
With preset quantities below this value, the “small” pumping rate is
relayed to the ULTRASAMPLER
®
; with other quantities, the “me-
dium” rate is relayed.
medium/high quantity
With preset quantities above this value, the “high” pumping rate is
relayed to the ULTRASAMPLER
®
; with other quantities, the
“me-
dium” rate is relayed.
Exp. Tour Vol
The preset tour quantity entered here is taken over, a new query at
the start of the tour does not occur again.
Motor CIP-Frequency
Rotational frequency of motor during cleaning
(1250)
Correction Factors
Correction of fat quantity during intake. In case of different intake quantities,
above-average fat values can be corrected.
Low Estimate Range
correction factor for fat quantity (Input in %1/x)
.. Operative up to
Quantity up to which the first correction factor applies (Input in l/min)
Middle Estimate Range
correction factor for fat quantity (Input in %1/x)
.. Operative up to
Quantity up to which the second correction factor applies. (Input in
l/min)
High Estimate Range
correction factor for fat quantity (Input in %1/x)
Start delay high amount
When a preset quantity is greater than the quantity to which the
second correction factor applies („…Operative up to “) the value
entered here will be used instead of the value of the start delay for
a single sample. (Input in ms)