APEX / SILAS
Pressurized Cabinet
Putting out of operation
Rev. -
01-3704_7D0001_Manual_APC-SPC_20200617_jrs_en.docx
Page 35 of 40
9
Putting out of operation
Shut-down
Proceed as follows in order to switch off the APEX (SILAS) pressurized cabinet:
-
Make sure that there is no explosive atmosphere.
-
Switch off the fuse or the main switch for the APEX (SILAS) pressurized
cabinet and lock it against unintended restart.
-
Observe the specified waiting times before opening the door of the APEX
(SILAS) pressurized cabinet.
Cooling and discharge times
CAUTION
WHEN OPENING THE APEX (SILAS) PRESSURIZED CABINET THAT HAS
COOLING OR DISCHARGE TIMES.
Hot assemblies and/or assemblies with a discharge time may be integrated
within the APEX (SILAS) pressurized cabinet.
Observe the marked waiting time before opening
Observe the operating instructions
APEX (SILAS) pressurized cabinet with assemblies requiring a waiting time for
cooling or discharge are labelled with a warning sign on the front.
Procedure:
-
Deactivate the pressurized compartment of the APEX (SILAS) pressurized
cabinet using the main switch for the internal application.
-
Observe the waiting time (waiting time marked on the sign).
-
APC can be opened.