TESTING THE INSTALLATION
PAGE 25
6. TESTING THE INSTALLATION
It is advisable to test the state of the cellular network signal as well as the
operation of the directories when installing the Cv3. If the cellular signal
strength is low, additional measures may be required to ensure reliable
operation.
Checking the Cellular Connection
The Cv3 has been outfitted with LED indicators on the top of the unit. The
Phone LED and Signal LEDs are used to determine the state of the phone
and signal strength of the connection.
STATE
PHONE LED
SIGNAL LEDs
Hardware Failure
Solid Red
1 Rolling Red
Invalid SIM Card
Off
1 to 4 Solid
Yellow
Not Registered
Solid Red
4 Solid Yellow
No Signal
Solid Red
4 Flashing Red
Invalid MIN, Not Registered
Flashing Red
4 Solid Yellow
Invalid MIN, Registered
Flashing Green
1 to 4 Solid Green
Invalid MIN, Roaming
Flashing Yellow
1 to 4 Solid Green
Roaming
Solid Yellow
1 to 4 Solid Green
Operation Good, Weak signal
Solid Green
1 or 2 Solid Green
Operation Good, Strong signal
Solid Green
3 or 4 Solid Green
Starting A Call
Flashing Red/Green
1 to 4 Solid Green
Ringing
Flashing Red/Green
1 to 4 Solid Green
Call In Progress
Flashing Red/Green
1 to 4 Solid Green
Verifying the Telephone Numbers
All of the telephone numbers that are entered into a directory should be
carefully checked to guarantee that they are valid numbers and that local
(or long distance dialing) is appropriate. After the Cv3 has been
programmed, a test should be performed to confirm that these numbers are
called correctly.
Содержание B1277-HSPA
Страница 2: ......
Страница 36: ...TECHNICAL DRAWINGS PAGE 33 9 TECHNICAL DRAWINGS Unit Dimensions...